English
Language : 

FM-106 Datasheet, PDF (1/2 Pages) Tyco Electronics – Broadband Frequency Doubler, 400 - 6000 MHz Output
Broadband Frequency Doubler,
400 - 6000 MHz Output
V 3.00
Features
n Hermetic Flatpack
n Multioctave Operation
n Conversion Loss: 11 dB Midband
n Impedance: 50 Ohms Nominal
n Maximum Input Power: 300 mW Max.
n MIL-STD-202 Screening Available
Description
FP-2
A transmission line balun transformer connects to Schottky
diodes arranged in a bridge configuration. This design
allows balanced activation of all diodes, and yields
excellent conversion loss, and odd-order term suppression.
Pin Configuration
Pin No.
1
2
3
4
Function
GND
GND
GND
Input
Pin No.
5
6
7
8
Function
GND
GND
GND
Output
Electrical Specifications1: TA = -55°C to +85°C
Parameter
Frequency Range
Conversion Loss
Spurious (Referred to
Output F2 Level)
VSWR
Conversion Loss as
Quadrupler
Test Conditions
Input
Output
F1
F3
Input
—
Frequency
200 - 3000
400 - 6000
200 - 400 MHz
400 - 2500 MHz
2500 - 3000 MHz
200 - 500 MHz
500 - 3000 MHz
600 - 2400 MHz
2400 - 9000 MHz
200 - 500 MHz
500 - 3000 MHz
—
Units
MHz
MHz
dB
dB
dB
dB
dB
dB
dB
Ratio
Ratio
dB
Min
Typ
—
—
—
—
—
—
—
—
—
—
20
—
15
—
25
—
20
—
—
<3.0:1
—
<2.0:1
—
30
1. All specifications apply when operated at +13 dBm input power with 50 ohm source and load impedance.
Max
—
—
14.5
13.0