English
Language : 

FM-105 Datasheet, PDF (1/2 Pages) Tyco Electronics – Plug-In Frequency Doubler, 20 - 1500 MHz Output
Plug-In Frequency Doubler,
20 - 1500 MHz Output
V 3.00
Features
n Relay Header Case
n Multioctave Frequency Coverage
n Conversion Loss: 12 dB Midband
n Impedance: 50 Ohms Nominal
n Maximum Input Power: 300 mW Max.
n MIL-STD-883 Screening Available
Description
A transmission line balun transformer connects to Schottky
diodes arranged in a bridge configuration. This design
allows balanced activation of all diodes, and yields
excellent conversion loss, and odd-order term suppression.
RH-3
Pin Configuration
Pin No.
1
2
3
4
Function
Input
GND
GND
GND
Pin No.
5
6
7
8
Function
GND
GND
GND
Output
Electrical Specifications1: TA = -55°C to +85°C
Parameter
Frequency Range
Conversion Loss
Spurious (Referred to
Output F2 Level)
VSWR
Conversion Loss as
Quadrupler
Test Conditions
Input
Output
F1
F3
Input
—
Frequency
10 - 750
20 - 1500
10 - 500 MHz
500 - 750 MHz
10 - 100 MHz
100 - 300 MHz
300 - 500 MHz
500 - 750 MHz
30 - 300 MHz
300 - 900 MHz
900 - 1500 MHz
1500 - 2250 MHz
—
—
Units
MHz
MHz
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB+
Ratio
dB
Min
Typ
—
—
—
—
—
—
—
—
25
—
20
—
15
—
10
—
35
—
30
—
25
—
20
—
—
<2.0:1
—
30
1. All specifications apply when operated at +13 dBm input power with 50 ohm source and load impedance.
Max
—
—
14.5
15.5
—
—
—
—
—
—
—
—
—
—