English
Language : 

FM-104 Datasheet, PDF (1/2 Pages) Tyco Electronics – Broadband Frequency Doubler, 150 - 3000 MHz Output
Broadband Frequency Doubler,
150 - 3000 MHz Output
V 3.00
Features
n Hermetic Flatpack
n Multioctave Frequency Coverage
n Conversion Loss: 10 dB Midband
n Impedance: 50 Ohms Nominal
n Maximum Input Power: 300 mW Max.
n MIL-STD-202 Screening Available
Description
A transmission line balun transformer connects to Schottky
diodes arranged in a bridge configuration. This design
allows balanced activation of all diodes, and yields
excellent conversion loss, and odd-order term suppression.
FP-3
Pin Configuration
Pin No.
1
2
3
4
5
Function
GND
GND
Input
GND
GND
Pin No.
6
7
8
9
10
Function
GND
GND
Output
GND
GND
Electrical Specifications1: TA = -55°C to +85°C
Parameter
Frequency Range
Conversion Loss
Spurious (Referred to
Output F2 Level)
VSWR
Conversion Loss as
Quadrupler
Test Conditions
Input
Output
F1
F3
Input
—
Frequency
75 - 1500
150 - 3000
75 - 1000 MHz
1000 - 1500 MHz
75 - 1000 MHz
1000 - 1500 MHz
225 - 3000 MHz
3000 - 4500 MHz
—
—
Units
MHz
MHz
dB
dB
dB
dB
dB
dB
Ratio
dB
Min
Typ
Max
—
—
—
—
—
—
—
—
12
—
—
14
20
—
—
17
—
—
20
—
—
17
—
—
—
<2.5:1
—
—
26
—
1. All specifications apply when operated at +13 dBm input power with 50 ohm source and load impedance.