English
Language : 

ETC16-4-2-3 Datasheet, PDF (1/2 Pages) Tyco Electronics – E-Series RF 1:4 Transmission Line Step-up Transformer 500 - 2500 MHz
E-Series RF 1:4 Transformer — 500 - 2500 MHz
ETC1.6-4-2-3
ETC1.6-4-2-3
E-Series RF 1:4 Transmission Line Step-up Transformer
500 - 2500 MHz
Features
• Surface Mount
• 1:4 Impedance Ratio
• CT on Secondary
• Available on Tape & Reel
SM-22 Package
0.050
(1.27)
0.030
(0.762)
0.150
(3.81)
0.030
(0.762)
0.150 MAX
(3.81 MAX)
0.150
(3.81)
0.030
(0.762)
0.065
(1.65)
0.055
(1.397)
0.190
(4.83)
Description
M/A-COM’s ETC1.6-4-2-3 is a 1:4 RF transmission line step-up
transformer in a low cost, surface mount package. Ideally suited
for high volume cellular and wireless applications. Typical
applications include single to balanced mode conversion and
impedance matching.
0.100
(2.54)
Schematic
Primary Dot 5
0.130
(3.30)
0.030
(0.762)
1 Secondary Dot
2 Secondary CT
Electrical Specifications @25°C
Parameter
Frequency Range 500 - 2500
Insertion Loss (fL - fU)
500 - 750 MHz
750 - 1200 MHz
1200 - 2500 MHz
Units
MHz
dB
dB
dB
Primary 4
3 Secondary
Nominal
—
—
—
—
Maximum
—
3.0
1.0
3.0
Mean (x)
—
—
0.22
—
Sigma (σ)
—
—
0.159
—
Note: Mean and Sigma calculated from average loss at @ (fU - fL)/2 + fL
Please Note that the photograph above indicates package only, not actual unit.
V2.00
S 0206 G
www.macom.com
M/A-COM Division of AMP Incorporated s North America: Tel. (800) 366-2266, Fax (800) 618-8883 s Asia/Pacific: Tel.+85 2 2111 8088,
Fax +85 2 2111 8087 s Europe: Tel. +44 (1344) 869 595, Fax+44 (1344) 300 020
AMP and Connecting at a Higher Level are trademarks.