Features
q Fully Hermetic Package
q 0.6 dB Typical Midband Loss
q 28 dB Typical Midband Isolation
q 1.2:1 Typical Midband VSWR
q MIL-STD-202 Screening Available
Guaranteed Specifications* (From - 55°C to + 85°C)
Part Number
DS-313
Frequency Range
10-2000 MHz
Insertion Loss (Less Coupling)
20-1000 MHz
1.1
10 - 1500 MHz
1.3
1500 - 2000 MHz
1.8
Isolation
20 - 1000 MHz
23
10 - 1500 MHz
18
1500 - 2000 MHz
12
Amplitude Balance
20 - 1000 MHz
0.3
10 - 1500 MHz
0.4
1500 - 2000 MHz
0.6
Phase Balance
20 - 1000 MHz
4°
10 - 1500 MHz
6°
1500 - 2000 MHz
8°
VSWR(All Ports)
20 - 1000 MHz
1.5
10 - 1500 MHz
1.6
1500 - 2000 MHz
1.8
DSS-313
10 - 2000 MHz
1.1 dB Max.
1.3 dB Max
1.8 dB Max.
22 dB Min.
18 dB Min.
12 dB Min.
0.3 dB Max.
0.4 dB Max.
0.6 dB Max.
5° Max.
8° Max.
11° Max.
1.5 Max.
1.6 Max.
1.8 Max.
DS-/DSS-313
FP-2
PIN 0.015 DIA ±0.005
(0.038 ±0.13)
8 PLACES
123 4
567 8
V2.00
0.312 MIN TYP
(7.9 MIN)
0.385 ± 0.020
(9.8 ± 0.5)
0.080 (2.0)
0.100 (2.5)
0.250 (6.3)
0.51
(12.9 ±0.5)
0.350 (8.9)
0.150 MAX
(3.8 MAX)
0.060 (1.5)
Dimensions in ( ) are in mm.
Unless Otherwise Noted: .xxx = ±0.010 (.xx = ±0.25)
.xx = ±0.02 (.x = ±0.5)
WEIGHT (APPROX.): 0.09 OUNCES 2.5 GRAMS
Operating Characteristics
Impedance
50 Ohms Nominal
Maximum Power Rating or Input Power
250 mW Max.
Internal Load Dissipation
50 mW Max.
*All specifications apply with 50 ohm source and load impedance.
Pin Configuration
Part Number
Σ
Output C
Output D
DS-313
P1
P4
P8
Case and all other pins are ground.
DSS-313
P1
P2
P4
SF-1
Dimensions in ( ) are in mm.
Unless Otherwise Noted: .xxx = ±0.010 (.xx = ±0.25)
WEIGHT (APPROX.): 0.07 OUNCES 2 GRAMS
M/A-COM Division of AMP Incorporated s North America: Tel. (800) 366-2266, Fax (800) 618-8883 s Asia/Pacific: Tel. +85 2 2111 8088, Fax +85 2 2111 8087
s Europe: Tel. +44 (1344) 869 595, Fax +44 (1344) 300 020
www.macom.com
AMP and Connecting at a Higher Level are trademarks.
Specifications subject to change without notice.
6-30