English
Language : 

CSJ-38-71010 Datasheet, PDF (1/1 Pages) Tyco Electronics – Solid State Hybrid Voltage Sensor
Catalog 1308242
Issued 3-03
P&B
Fixed Pick-up and
Adjustable Drop-out
Adjustable Pick-up
and Drop-out
Sensing Modes
The CS can be used as an over or undervoltage sensor, depending upon
whether the load is connected to the normally closed (NC) or normally open
(NO) contacts of the sensor’s output relay.
Overvoltage sensor – The NC contacts are used. The relay remains de-
energized until an overvoltage is sensed.
Undervoltage sensor – The NO contacts are used. The relay remains en-
ergized until the voltage decreases to the preset level, where the sensor
de-energizes the relay.
CS series
Solid State Hybrid Voltage Sensor
• Close differential
• Choice of two types
– Fixed pick-up and knob adjustable drop-out
– Knob adjustable pick-up and drop-out
• Internal 2 Form C (DPDT) output relay
File E22575
File LR15734
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Engineering Data
Power Requirement: Typically less than 3VA or 3W.
Duty Cycle: Continuous.
Repeatability: ± 1%, max.
Response Time: 10-25 ms, typ.
Internal Relay Contact Arrangement: 2 Form C (DPDT).
Internal Relay Contact Rating: 10A @ 28VDC , res., or 120VAC, 80% p.f.
Reverse Polarity Protection: On DC types.
Temperature Range: -10°C to +55°C.
Temperature Coefficient: 0.2%/°C, max.
Enclosure: Plastic dust cover.
Mounting: 8-pin octal style plug. Fits either 27E122 or 27E891 (snap-on)
screw terminal sockets.
Weight: 8 oz. (227g) approximately.
Adjustable Voltage Sensor Operation
RELAY
ENERGIZED
HYSTERISIS
2 VOLTS
RELAY
DE-ENERGIZED
Note 1 – As voltage increases, the
relay will pick-up at its selected
point and remain energized while
voltage is maintained at that level or
higher.
Note 2 – As voltage decreases, af-
ter pick-up, the relay will drop-out at
its selected point.
Note 3 – Minimum hysterisis, the
voltage differential between pick-up
and drop-out, is typically 2% of
pick-up.
NOTE 1
NOTE 2
Ordering Information –
Distributors are more likely to stock boldface items.
Fixed Pick-Up and Adjustable Drop-Out
Part Number
Pick-Up
(Volts)
Drop-Out Range
(Volts)
CSJ-38-71010
105
CSL-38-31010
22
90-103
16-21
Maximum
Voltage
140VAC (50/60 Hz.)
32VDC
Adjustable Pick-Up and Adjustable Drop-Out
Part Number Pick-Up Range Drop-Out Range*
(Volts)
(Volts)
Maximum
Voltage
CSJ-38-70010
CSL-38-30010
CSL-38-40010
CSL-38-60010
92-140
20-30
40-58
92-140
90-138
18-28
38-56
90-138
150VAC (50/60 Hz.)
32VDC
60VDC
150VDC
* Actual maximum drop-out voltage is the selected pick-up voltage less the hysterisis
voltage.
Outline Dimensions
.600 MAX.
(15.24)
2.937 MAX.
(76.60)
.560
(14.22)
1.781 MAX.
(42.24)
.875
(22.23)
1.187
(30.15)
Wiring Diagrams – Bottom Views
(pins numbered clockwise from keyway)
AC
INPUT
+ DC -
INPUT
Dimensions are shown for
1302 reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.