English
Language : 

CGB-38-70010M Datasheet, PDF (1/2 Pages) Tyco Electronics – CG series CMOS IC Time Delay Relay
Catalog 1308242
Issued 3-03
P&B
CG series
CMOS IC Time Delay Relay
• Repeatability to .05%
• Choice of timing modes
– Delay on operate
– Delay on release
– Interval on
• Knob adjustable
• 10A output relay with DPDT contacts
• Various models time from 0.5 sec. to 100 min.
File E22575
File LR15734
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Timing Modes
Delay on operate – Delay period begins when input voltage is applied. At
the end of the delay period, the relay will operate and will not release until
input voltage is removed. Reset occurs when input voltage is reapplied.
INPUT
ON
VOLTAGE OFF
N.O. RELAY ON
CONTACTS OFF
TIME
➛
Contact Data @ 25°C
Arrangements: 2 Form C (DPDT).
Material: Silver-cadmium oxide alloy.
Rating: 10A @ 30VDC or 277VAC, resistive; 1/2 HP @ 250VAC;
1/3 HP @ 120VAC.
Expected Mechanical Life: 10 million operations.
Expected Electrical Life: 100,000 operations, min., at rated load.
Delay on release – Input voltage must be applied continuously to operate
the internal relay. When the control switch is closed, the relay energizes.
When the control switch is opened, timing begins. When timing is
complete, the relay will de-energize. Time may be reset to zero during
timing by closing the control switch.
CONTROL ON
SWITCH OFF
N.O. RELAY ON
CONTACTS OFF
TIME
➛
Interval on – The relay energizes and timing begins when input voltage is
applied. At the end of the time delay period the relay will de-energize.
Reset is accomplished by removing, then reapplying, the input voltage.
INPUT
ON
VOLTAGE OFF
N.O. RELAY ON
CONTACTS OFF
TIME ➛
Initial Dielectric Strength
Between Open Contacts: 500V rms, 60 Hz.
Between All Other Conductors: 500V rms, 60 Hz.
Input Data @ 25°C
Voltage: 120VAC and 24VDC.
Power Requirement: AC Types: Typically less than 3 VA.
DC Types: Typically less than 3 W.
Transient Protection: Yes.
Reverse Voltage Protection: Yes.
Input Voltages & Limits @25°C
Voltage
Type
Nominal
Voltage
AC
120
DC
24
Minimum
Voltage
105
20
Maximum
Voltage
130
32
Note: DC voltage must be filtered (5% p-p ripple max. at nom. voltage).
AC models will operate on 50 or 60 Hz.
Timing Specifications
Timing Ranges: From 0.5 to 5.0 sec. through 10 to 100 min.
Timing Adjustment: Knob adjustable.
Tolerance (for AC units add ±1/2 cycle 60 Hz.):
Knob Adj. Types:–0, +10% of max. specified at high end of timing range;
+0, –10% of min. specified at low end.
Delta Time (for AC units add ±1 cycle 60 Hz.): ± 2%, typ.; ± 5%, max.
Repeatability (including first cycle of operation):
AC: ± 0.1%, typ.; ± 0.5%, max.; but not less than ± 16 ms.
DC: ± 0.05% typ.; ± 0.1% max.; but not less than ± 3 ms.
Release Time: 30 ms, typ.; 45 ms, max.
Recycle Time: AC: 40 ms, typ.; 60 ms, max.
DC: 30 ms, typ.; 45 ms, max.
Dimensions are shown for
1220 reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Environmental Data
Temperature Range: Storage: -40°C to +85°C.
Operating: -10°C to +55°C.
Mechanical Data
Termination: 8- or 11-pin octal style plug.
Enclosure: Yellow plastic case. Knob adjustable types have dial scale for
reference only.
Sockets: Models with 8-pin base fit either 27E122 or 27E891 (snap-on)
screw terminal sockets. 11-pin types fit either 27E123 or
27E892 (snap-on) screw terminal sockets.
Weight: 8 oz. (227g) approximately.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.