6VJ1_11 Datasheet, PDF (1/3 Pages) Tyco Electronics – Power Entry Module with Voltage Selection and Fusing | |||
|
J Series
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
Power Entry Module with Voltage Selection and Fusing
UL Recognized
CSA Certiï¬ed
Front View, all models
6J4
6HJ4
J Series
⢠Power entry module with North American style
3AG fuse holder
⢠2 or 4 voltage selection
⢠Compact snap-in design
⢠Two element circuit provides basic
EMI attenuation
⢠Available with minimal leakage current suitable
for medical applications (HJ models)
⢠Also available without ï¬lter (VJ models)
Ordering Information
6 H J 4 -4
Speciï¬cations
Maximum leakage current each Line to Ground:
6HJ4 or
6J4 Models nonâï¬ltered
@250 VAC 50 Hz:
500 ïA
5 ïA
Hipot rating (one minute):
Line to Ground:
Line to Line:
1550 VAC
1450 VDC
Operating Voltage:
suï¬x - 1 or - 4 models:
suï¬x - 2 models:
100, 120, 220 or 240VAC
115 or 230 VAC
Operating Frequency:
50/60 Hz
Rated Current:
6A
Required Fuse:
.25 x 1.25
(not included)
Available Voltage Selections
1 - Four (nonâï¬ltered versions)
2 â Two
4 or blank â Four (ï¬ltered versions)
Filtered Indicator
1 â Nonâï¬ltered
4 â Filtered
J Series
Filter Type
H â Medical
V â Non-ï¬ltered
Blank â general purpose
Current Rating
6A
Available Part Numbers
Nonâï¬ltered models
6VJ1
6VJ1-2
General Purpose Filters
6J4
6J4-2
Medical Filters
6HJ4-4
6HJ4-2
172
Dimensions are in inches and millimeters unless otherwise speciï¬ed. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Speciï¬cations subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
|
▷ |