English
Language : 

6VJ1 Datasheet, PDF (1/4 Pages) Tyco Electronics – Voltage Selecting and Fused Connector with Optional RFI Power Line Filter for General Purpose Applications for UL544 Health Care Equipment
J Series
CORCOM Product Guide
Voltage Selecting and Fused Connector with Optional RFI Power Line Filter for
General Purpose Applications for UL544 Health Care Equipment
UL Recognized
CSA Certified
Front View, All Models
6J4/6J4-2
Terminal View
6HJ4-1/6HJ4-2
Terminal View
J Series
The most widely accepted of all the power entry modules,
the J series combines an IEC connector, 2-voltage, or 4-
voltage selection, and a North American fuseholder. It
features a compact snap-in design and a unique voltage
selector card.
J4 Models - This general purpose filter provides
susceptibility protection from line-to-ground noise on the
power line and acts as a high frequency “clean-up” filter for
more complex emissions applications.
HJ4 Models - This medical filter provides susceptibility
protection without the leakage current associated with line-
to-ground capacitors. Designed to allow equipment to
meet UL544 medical specifications for patient care and
non-patient care equipment, the HJ filter has a maximum
leakage current of 2µA at 120 VAC 60 Hz. See Appendix
C for more information on medical applications and UL
standards.
Equipment rating labels and mounting clips for thicker
panel widths are available as accessories.
For more information on UL544 specifications, see
Appendix C.
Note: When using the models with an IEC connector,
remember that the leakage current of the companion line
cord, GA400, is more significant than that of the filter -
which may disqualify this line cord from use in patient care
applications.
Voltage Selection
Unfiltered and Filtered Models
Open cover door and rotate fuse-pull lever to left. Select
operating voltage by orienting voltage selection card,
desired voltage on top left side. Push card firmly into
module slot. Rotate fuse-pull lever back into normal
position and re-insert fuse into holders. Use caution in
selecting correct fuse value.
Unfiltered Models
Part Number
6VJ1
6VJ1-2
Available Voltage Selection
Positions
4
2
Unfiltered Models
Part Number
6VJ4
6J4-2
6HJ4-4
6HJ4-2
Available Voltage
Selection
RFI Filter
Positions
Type
4
General Purpose1
2
General Purpose1
4
Medical2
2
Medical2
Note 1: General purpose filter for susceptibility applications
Note 2: Medical line filter for very low leakage UL544 health care requirements
114
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
www.corcom.com
www.tycoelectronics.com