English
Language : 

6-1393298-5 Datasheet, PDF (1/4 Pages) Tyco Electronics – Automotive Relays Plug-in Mini ISO Relays
Automotive Relays
Plug-in Mini ISO Relays
VF4A (Standard, Shrouded and Weatherproof)
n Pin assignment similar to ISO 7588 part 1
n Plug-in terminals
n Customized versions on request
– Integrated components (e.g. resistor, diode)
– Customized marking
– Special covers (e.g. brackets, shrouded)
Typical applications
Cross carline up to 40A for example: ABS control, blower fans, car alarm,
cooling fan, Electric Power Steering, energy management, engine control,
fuel pump, heated front screen, lamps: front, rear, fog light, main switch/
supply relay, valves, wiper control.
Contact Data
Contact arrangement
1 form C, 1 CO
Rated voltage
12VDC
Limiting continuous current,
form A/form B
NO/NC
23°C
60/45A
85°C
40/30A
125°C
17/12A
Limiting making current1), form A/form B
120/45A
Limiting breaking current, form A/form B
60/40A
Limiting short-time current
overload current, ISO 8820-32)
1.35 x 40A, 1800s
2.00 x 40A, 60s
6.00 x 40A, 1s
Jump start test, ISO 16750-1
24VDC for 5min,
conducting nominal current at 23°C
Contact material
silver based
Min. recommended contact load3)
1A at 5VDC
Initial voltage drop,
form A (NO) contact at 40A, typ./max.
60/200mV
form B (NC) contact at 30A, typ./max.
60/250mV
Frequency of operation at nominal load
6 ops./min (0.1Hz)
Operate/release time typ.
7/2ms4)
Electrical endurance
>1x105 ops.
resistive load, form A (NO) contact
40A, 14VDC
resistive load, form B (NC) contact
30A, 14VDC
Max. DC load breaking capacity
FVF4Aco_fcw1_bw
Contact Data (continued)
Mechanical endurance
>1x106 ops.
1) The values apply to a resistive or inductive load with suitable spark suppression and
at maximum 14VDC for 12VDC or 28VDC for 24VDC load voltages. For a load current
duration of maximum 3s for a make/break ratio of 1:10.
2) Current and time are compatible with circuit protection by a typical automotive fuse.
Relay will make, carry and break the specified current.
3) See chapter Diagnostics of Relays in our Application Notes or consult the internet at
http://relays.te.com/appnotes/
4) For unsuppressed relay coil. A low resistive suppression device in parallel to the relay
coil increases the release time and reduces the lifetime caused by increased erosion
and/or higher risk of contact tack welding.
Coil Data
Rated coil voltage
12/24VDC
Coil versions, DC coil
Coil
Rated
Operate Release
Coil
Rated coil
code
voltage
voltage
voltage resistance5) power5)
VDC
VDC
VDC
Ω±10%
W
F
12
7.2
1.2
90
1.6
H
24
14.4
2.4
360
1.6
5) Without components in parallel.
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Coil operating range
TEVF4_OVR1
Does not t
the tempe
the contac
E = pre-en
Load limit curve 1: arc extinguishes during transit time (changeover contact).
Load limit curve 2: safe shutdown, no stationary arc (make contact).
Load limit curves measured with low inductive resistors verified for 1000 switching events.
Does not take into account the temperature rise due to the contact current
E = pre-energization.
03-2012, Rev. 0312
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.
Datasheets and product specification ac-
cording to IEC 61810-1 and to be used only
together with the ‘Definitions’ section.
1
Datasheets and product data is subject to the Datasheets, product data, ‘Definitions’ sec-
terms of the disclaimer and all chapters of
tion, application notes and all specifications
the ‘Definitions’ section, available at
are subject to change.
http://relays.te.com/definitions