English
Language : 

41063 Datasheet, PDF (1/2 Pages) Tyco Electronics – Power Relay
General Purpose Relays
Power Relay 410 63 125°C
I 1 pole 16 A, 1 NO or 1 NC contact
I Switching capacity 4000 VA
I Coil power 360 mW
I 4 kV / 8 mm coil-contact, insulation to VDE 0631 and 0700
I Ambient temperature up to 125°C
I Quick connect terminals for load side
I WG version: Materials in accordance to IEC 60335-1
I RoHS compliant (Directive 2002/95/EC)
as per product date code 0349
Applications
White goods appliances, oven control, electric heating, power
suppplies, air conditionning, motors, magnetic valves
Approvals
V Z REG.-Nr. 3725,
E214025
Technical data of approved types on request
Contact data
Contact configuration
Contact set
Type of interruption
Rated current
Rated voltage / max.switching voltage AC
Limiting making capacity, max 4 s, duty factor 10%
Contact material
Mechanical endurance
Rated frequency of operation with / without load
1NO or 1NC
single contact
micro disconnection
16 A
240/400 VAC
25 A
AgCdO, AgNi
1x106 cycles
10 / 600 min-1
Contact ratings
Type
Load
NO contact 16 A, 250 VAC, resistive, 125°C
NO contact 12 A, 250 VAC, resistive, 70°C
NC contact 16 A, 250 VAC, resistive, 125°C
NO contact 10 A, 400 VAC, resistive, 125°C
NO contact 12 A, 250 VAC, cosϕ=0.6, 125°C
Cycles
1x105
4,5x105
1,5x105
5x104
5x104
Coil data
Rated coil voltage DC coil
Coil power DC coil
Operative range
Coil insulation system according UL1446
6...60 VDC
typ. 360 mW
1
Class F
Coil versions, DC-coil
Coil
Rated
Operate
Release
Coil
Rated coil
code
voltage
voltage
voltage
resistance
power
VDC
VDC
VDC
Ohm
mW
054
6
3.6
0.45
100+10%
360
053
9
5.5
0.68
230+10%
352
050
12
7.3
0.9
400+10%
360
046
24
14.6
1.8
1600+10%
360
043
48
29.2
3.6
6400+10%
360
042
60
36.5
4.5
10000+10%
360
All figures are given for coil without preenergization, at ambient temperature +23°C
Other coil voltages on request
F0248-AA
Datasheet
Rev. EK1
Issued 2005/11
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
1
‘Schrack’ section.
Specifications subject to
change.