English
Language : 

40957 Datasheet, PDF (1/2 Pages) Tyco Electronics – Special Load PCB Relay
Special Load PCB Relay 409 57, 409 77
1 pole 16 A, for high inrush currents,
mono- or bistable
Features
• Specifically designed to handle high inrush currents
• 1 N/O contact
• DC- or bistable version
• 4 kV / 8 mm coil-contact
Applications
Lighting controls, filament loads, motors and electrovalves
F0249-A
Contact data
Configuration
Type of contact
Rated current
Rated voltage / max.breaking voltage AC
Rated voltage / max.breaking voltage DC
Maximum breaking capacity AC
Make current (max. 4 s at duty cycle 10%)
Peak inrush current
Contact material
Z (409 57 only)
Technical data of approved types on request
1 N/O contact
single contact
16 A
250 Vac / 440 Vac
250 Vdc / 250 Vdc
4000 VA
25 A
120 A
AgSnO2
Contact ratings
Type
Load
409 57 / 77 16 A, 250 Vac, cosϕ=1
409 57 / 77 1200 W, fluorescent lamps, 100 µF
409 57 / 77 2500 W, Filament lamps
409 57 / 77 800 W, Dulux lamps, 100 µF
409 57 / 77 capacitive load 10 A, 140 µF
Operations
1.5x105
3x104
3x104
2x104
3x104
Standard
EN 61058-1
Coil data
Nominal voltage
Nominal coil power
Operate category
monostable DC coil
5...110 Vdc
530 mW
2/b
bistable, 1 coil
Coil versions monostable
Coil
Nominal
Pull-in
Release Maximum
Coil
Coil
code voltage
voltage
voltage
voltage resistance
current
Vdc
Vdc
Vdc
Vdc
c
mA
002
12
8.6
0.9
16.0
285+10%
42.1
001
24
17.3
1.8
31.0
1040+10%
22.0
007
48
34.5
3.6
62.0
4580+10%
10.5
003
60
43.2
4.5
78.0
6300+10%
9.5
005
110
79.3
7.5
142.0
20000+10%
5.5
All figures are given for coil without preenergization, at ambient temperature +20°C
Other coil voltages on request