4. TOOL MAINTENANCE
It is recommended that the extraction tool be
inspected when you receive it and at regularly
scheduled intervals. The tool is not repairable and
should be replaced when it is worn or damaged. Store
the tool in a clean, dry place and clean the tool with a
soft, lint--free cloth.
Figure 1
1. INTRODUCTION
Extraction Tool 844751--2 is designed to remove
AMPINNERGY* wire--to--board (WTB) contacts and
Posi--Mate contacts from connector housings. Read
these instructions carefully before using the tool.
NOTE
i
Dimensions in this instruction sheet are in metric
units [with U.S. customary units in brackets].
Figures are not drawn to scale.
5. REPLACEMENT
Order tools through your representative, or call
1--800--526--5142, or send a facsimile of your
purchase order to 717--986--7605, or write to:
CUSTOMER SERVICE (038--035)
TYCO ELECTRONICS CORPORATION
PO BOX 3608
HARRISBURG PA 17105--3608
Wire- Entry End
of Housing
Reasons for reissue of this instruction sheet are
provided in Section 6, REVISION SUMMARY.
2. DESCRIPTION
The extraction tool consists of a plastic handle, and a
steel blade tool tip with a chamfer. When properly
inserted into the housing contact cavity, the tool tip
functions as a latch release, depressing the locking
lance to allow the contact to be removed from the
housing.
3. EXTRACTION PROCEDURE (Figure 2)
1. Align the tip of the tool with the appropriate
contact cavity on the mating face of the housing.
Position the tip so that the chamfer is facing the
top of the contact cavity.
2. Hold wire, and gently insert tool tip into the
contact cavity until the tip is positioned under the
locking lance.
3. Push down gently on the tool handle to release
the contact locking lance from its locking surface.
Pull back on the wire to remove contact from the
wire--entry end of the housing.
CAUTION
!
DO NOT use excessive force when extracting
contact from cavity. If you experience difficulty in
removing the contact, re- insert the tool tip,
making sure the tip is properly positioned in the
cavity, and try again.
Mating Face
of Housing
Chamfer on Tool
Tip Facing Top of
Contact Cavity
Wire
Locking
Lance
Figure 2
6. REVISION SUMMARY
Revisions to this instruction sheet include:
S Updated instruction sheet to corporate
requirements
E2010 Tyco Electronics Corporation, Harrisburg, PA TOOLING ASSISTANCE CENTER 1- 800- 722- 1111
All International Rights Reserved
PRODUCT INFORMATION 1- 800- 522- 6752
TE logo and Tyco Electronics are trademarks.
*Trademark. Other products, logos, and company names used are the property of their respective owners.
This controlled document is subject to change.
For latest revision and Regional Customer Service,
visit our website at www.tycoelectronics.com
1 of 1
LOC B