English
Language : 

408-4146 Datasheet, PDF (1/6 Pages) Tyco Electronics – The head must be installed in Pistol Grip Manual Handle Assembly
Terminating Head 58247-3
For MTA-156 Receptacle Connectors
Instruction Sheet
408-4146
19 FEB 08 Rev A
Locating
Pawl
Feed
Slide
Wire
Inserter
Mass Termination Assembly (MTA)-156
Insulation Displacement Contact (IDC)
Closed-End Receptacle Connectors
Tool
Base
Adjuster
(Insertion Rod)
With Lock
(Ramp)
Without Lock
(Ramp)
With Lock,
With
Polarizing Tabs
Without Lock,
With
Polarizing Tabs
Figure 1
1. INTRODUCTION
Terminating Head 58247–3 (shown in Figure 1) is
designed to terminate discrete wire, jacketed cable, or
ribbon cable in MTA–156 IDC closed–end receptacle
connectors with or without lock (ramp) and with or
without polarizing tabs. Slotted contacts for insulation
displacement termination are pre–assembled on
3.96–mm [.156–in.] centerlines in each color–coded
housing for a specific wire size.
The head must be installed in Pistol Grip Manual
Handle Assembly 58074–1 or Pistol Grip Pneumatic
Handle Assembly 58075–1. For head installation and
removal, refer to Instruction Sheet 408–6790 for the
manual handle assembly and 408–6789 for the
pneumatic handle assembly.
For detailed connector description and application
requirements, refer to Application Specification
114–1020.
Read these and all referenced instructions thoroughly
before using the head.
NOTE
i
All numerical values in this instruction sheet are
in metric units [with U.S. customary units in
brackets]. Dimensions are in millimeters [and
inches]. Figures are not drawn to scale.
Reasons for reissue of this instruction sheet are
provided in Section 8, REVISION SUMMARY.
Wire Inserter — forces the wire into the two slotted
beams of the contact. Note that it provides support for
the contact beams when applying insertion force on
the wire.
Adjuster (Insertion Rod) — is a piston for the wire
inserter and regulates wire inserter travel.
Feed Slide — automatically positions the connector
after each termination.
Locating Pawl (or Anti–Backup Pawl) — aligns the
connector for insertion, and retains it during
termination.
3. SETUP AND TEST INSPECTION
The adjuster (insertion rod) is preset for wire sizes 26
through 18 AWG. If the wire is being inserted too
deeply or not deeply enough inside the contact, it may
be necessary to adjust the depth of the wire inserter,
or in addition, if the pneumatic handle assembly is
being used, it may be necessary to adjust the air
pressure. Proceed as follows:
3.1. Setup
1. Determine the wire size, and select the
appropriate color–coded connector from Figure 2.
WIRE SIZE (AWG)
26
24
CONNECTOR COLOR CODE
Blue
Natural
2. DESCRIPTION
The head serves as a guide and support for the
connector during termination. Features of the head
(shown in Figure 1) and their function are as follows.
22
Red
20
Yellow
18
Orange
Figure 2
E2008 Tyco Electronics Corporation, Harrisburg, PA
TOOLING ASSISTANCE CENTER 1-800-722-1111
All International Rights Reserved
PRODUCT INFORMATION 1-800-522-6752
TE logo and Tyco Electronics are trademarks.
*Trademark. Other products, logos, and company names used are the property of their respective owners.
This controlled document is subject to change.
For latest revision and Regional Customer Service,
visit our website at www.tycoelectronics.com
1 of 6