English
Language : 

3ERK1 Datasheet, PDF (1/3 Pages) Tyco Electronics – High Performance Compact Power Line Filter
Corcom Product Guide
High Performance Compact Power Line Filter
RK Series
UL Recognized
CSA Certified
VDE Approved
Catalog: 1654001
Issue Date: 06.2011
1
RK Series
• Compact
• Single stage
• Chassis mount
• Significant differential mode performance
• Suitable for industrial machinery
• Low input leakage current makes it suitable for
portable equipment
Ordering Information
10 E RK 1
Input / Output Style
1 – .250 [6.3] spade terminals
RK Series
Leakage current designation
E – Low leakage (<0.5 mA)
Current Rating
3, 6, 10, 15 or 20A
Specifications
Maximum leakage current each Line to Ground:
@ 120 VAC 60 Hz:
0.16 mA
@250 VAC 50 Hz:
0.26 mA
Hipot rating (one minute):
Line to Ground:
Line to Line:
2250 VDC
1450 VDC
Rated Voltage (max):
250 VAC
Operating Frequency:
50/60 Hz
Rated Current:
3 to 20A
Operating Ambient Temperature Range
(at rated current Ir):
-10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the
maximum
operating
current (Io)
follows: Io
is calculated as
= Ir (85-Ta)/45
Electrical Schematic
LINE
LOAD
Available Part Numbers
3ERK1
10ERK1
20ERK1
6ERK1
15ERK1
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
65
For email, phone or live chat, please go to
te.com/help
corcom.com