3EQ1_11 Datasheet, PDF (1/3 Pages) Tyco Electronics – Highest Performance RFI Filters for Switching Power Supplies | |||
|
Q Series
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
Highest Performance RFI Filters for Switching Power Supplies
Q8
UL Recognized
CSA Certiï¬ed
VDE Approved
Q1
Q3
Q Series
⢠Speciï¬cally developed for switching power
supplies
⢠High attenuation for common and differential
mode interference
⢠Effective from 10kHz to 30MHz
⢠Optimized for attenuation and size
⢠3 or 6A versions available with IEC inlet
Ordering Information
6EQ8M
Suï¬x
M â Metric inserts (style 8 only)
Omit for standard or none
Input / Output Style
1 â .250 [6.3] spade terminals
3 â Wire leads
8 â IEC inlet* (line side)
Wire leads (load side)
Q Series
Leakage current designation
E â Low leakage (<0.5 mA)
V â Standard
Current Rating
3, 6 or 20A
Speciï¬cations
Maximum leakage current each Line to Ground:
3 & 20A
@120 VAC 60 Hz:
@250 VAC 50 Hz:
VQ Models
.73 mA
1.27 mA
EQ Models
.22 mA
.38 mA
6A
@120 VAC 60 Hz:
@250 VAC 50 Hz:
â
.29 mA
â
.51 mA
Hipot rating (one minute):
Line to Ground:
Line to Line:
2250 VDC
1450 VDC
Rated Voltage (max):
250 VAC
Operating Frequency:
50/60 Hz
Rated Current:
3 to 20A
Operating Ambient Temperature Range
(at rated current Ir):
-10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the
maximum
operating
current (Io)
follows: Io
is calculated as
= Ir ï(85-Ta)/45
Available Part Numbers
3EQ1
3EQ3
3EQ8
3EQ8M
6EQ1
6EQ3
6EQ8
6EQ8M
20EQ1
3VQ1
3VQ3
3VQ8
3VQ8M
20VQ1
Accessories
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
*IEC 60320-1 C14 inlet mates with C13 connector
58
Dimensions are in inches and millimeters unless otherwise speciï¬ed. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Speciï¬cations subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
|
▷ |