English
Language : 

2-1415012-1 Datasheet, PDF (1/3 Pages) Tyco Electronics – Force Guided Relay SR2M
General Purpose Relays
Force Guided Relays
Force Guided Relay SR2M
n 2 pole relay with force guided contacts according to EN 50205
n Reinforced insulation between poles
SCHRACK
Typical applications
Emergency shut-off, press control, machine control, elevator and escalator
F0188-D
control, safety relays
Approvals
VDE 116064, UL E214025, TUV 968/EZ 111, CQC0617015579
Technical data of approved types on request
Contact Data
Contact arrangement
1 form A + 1 form B contacts
(1 NO + 1 NC) or
2 form C contacts (2 CO)
According EN50205 only 1NO / 1NC (11-14 and 22-21 or 12-11 and
21-24) shall be used as force guided contacts.
Rated voltage
250VAC
Max. switching voltage
400VAC
Rated current
6A
Contact material
AgNi
Contact style single contact, force guided
1 form A + B, 1 NO + 1NC type A according to EN 50205
2 form C, 2CO type B according to EN 50205
Min. recommended contact load
5V/10mA
Initial contact resistance ≤100mΩ at 1A, 24VDC
≤20Ω at 10mA, 5VDC
Frequency of operation, with/without load
6/300min-1
Contact ratings, IEC60947-5-1,
on 1 form A (NO) contact
AC15-3A
DC13-6A
Mechanical endurance
10x106 operations
VZT
Coil Data (contunied)
Coil versions, DC-coil
Coil
Rated
Operate Release
Coil
Rated coil
code
voltage
voltage
voltage resistance power
VDC
VDC
VDC
Ω±10%1)
mW
015
15
11.3
1.5
321
701
018
18
13.5
1.8
483
671
021
21
16
2.1
630
700
024
24
18
2.4
823
700
036
36
27
3.6
1851
700
040
40
30
4.0
2286
700
048
48
36
4.8
32911)
700
060
60
45
6
51421)
700
080
85
63.8
8.5
91431)
790
110
110
83
11
172851)
700
1) Coil resistance ±12%.
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Coil Data
Coil voltage range
5 to 110VDC
Coil versions, DC-coil
Coil
Rated
Operate Release
Coil
Rated coil
code
voltage
voltage
voltage resistance power
VDC
VDC
VDC
Ω±10%1)
mW
005
5
3.8
0.5
35.7
700
006
6
4.5
0.6
51
706
009
9
6.8
0.9
116
698
012
12
9
1.2
206
699
04-2011, Rev. 0411
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Insulation
Initial dielectric strength
between open contacts
between contact and coil
between adjacent contacts
Clearance/creepage
between open contacts
between contact and coil
between adjacent contacts
Insulation to EN 50178, type of insulation
between contact and coil
between adjacent contacts
1500Vrms
4000Vrms
3000Vrms
microdisconnection
≥8/8mm
≥5.5/5.5mm
reinforced
reinforced
1
Datasheets and product data is subject to the Datasheets, product data, ‘Definitions’ sec-
terms of the disclaimer and all chapters of
tion, application notes and all specifications
the ‘Definitions’ section, available at
are subject to change.
http://relays.te.com/definitions