English
Language : 

2-1393812-0 Datasheet, PDF (1/7 Pages) Tyco Electronics – Cradle S Relay V23054/V23062
Signal Relays
Cradle S Relay V23054/V23062
AXICOM
n Strong magnet system and wide voltage range
n Highly reliable
n Contacts for signal loads and currents up to 5A
n DC coils operating voltage 6VDC to 220VDC; AC, latching and non-
latching coils on request
n Multi purpose relay
n Great variety of contact arrangements and materials to meet
specific applications
n Sockets for easy and quick mounting of relays
Typical applications
Press controls with high safety requirements (forcibly guided springs),
traffic and railroad signalling, motor vehicle traffic controls, power plants
and nuclear power plants controls
Contact Data
Product code block 3 B104/B110/
B604/B610/
C104/C110/
C404/C410/
F104/F105/
B112/B133
B612/B633
C112/C133
C422/C433
F110
Contact arrangement
max. 6 form C (6 CO) contacts or 6 form A (6 NO) contacts (see product code table)
Max. switching voltage 150VDC
36VDC
150VDC
36VDC
260VDC
125VAC
30VAC
125VAC
30VAC
250VAC
Rated current 2A
0.2A
2A
0.2A
5A
Limiting continuous current
at max. ambient temperature 2A
2A
2A
2A
5A
Breaking capacity max.
35 to 70W
5W, 5VA
35 to 70W
5W, 5VA
50 to 140W
see DC load breaking capacity curve below 50VA
-
50VA
-
500VA
Contact material silver, gold-flashed
gold F
silver, gold-flashed
gold F
silver, gold-flashed
Contact style single contact
single contact
bifurcated contacts bifurcated contacts
single contact
Frequency of operation, without load, max. 50 ops./s
max. 50 ops./s
max. 50 ops./s
max. 50 ops./s
max. 10 ops./s
Operate / release time typ.
16/2ms
16/2ms
16/2ms
16/2ms
16/2ms
Mechanical endurance app. 107 ops.
app. 107 ops.
app. 107 ops.
app. 107 ops.
app. 107 ops.
Max. DC breaking capacity, contact sets B1xx, C1xx
150
V_
120
U
100
70 W
80
Max. DC breaking capacity, contact sets F1xx
250
V_
200
U 150
140 W
100 W
100
80
60
50
safe breaking, no stationary arc
contact material Ag, gold flashed
40
40 W
60
50
40
safe breaking, no stationary arc
contact material Ag, gold flashed
30
50 W
30
0,3
0,4
0,5
0,6
0,8
1
1,5
2A
DC current [A]
I
20
0,2
0,3
0,4 0,5 0,6
0,8 1
1,5
2
3
4 5A
DC current [A] I
03-2012, Rev. 0312
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
1
Datasheets and product data is subject to the Datasheets, product data, ‘Definitions’ sec-
terms of the disclaimer and all chapters of
tion, application notes and all specifications
the ‘Definitions’ section, available at
are subject to change.
http://relays.te.com/definitions