n Low profile, therefore particularly suited for flat pack components
grouping
n For relays with 1 or 2 form C (CO) contacts:
- creepage and clearance distances between contacts and
frame >5mm or >10mm (depending on the relay version)
- dielectric strength between contacts and
frame 4kVrms or 6kVrms
Typical applications
measuring and control systems, alarm and security equipment, road traffic
and railway signaling systems
AXICOM
Contact Data A104 A106 A204 A206
Contact arrangement 4 form C, 6 form C, 4 form C, 6 form C,
(4 CO)
(6 CO)
(4 CO)
(6 CO)
Max. switching voltage 250VDC 250VDC 30VDC
30VDC
250VAC 250VAC 36VAC
36VAC
Limiting continuous current
≤50°C ambient
2A
2A
2A
2A
≤75°C ambient
1A
1A
1A
1A
Limiting making/breaking current
3A1)
3A1)
0.2A
0.2A
Contact material
Ag,
Ag,
Gold F2)
Gold F2)
Au-flashed Au-flashed
Contact style
bifurcated contacts
Frequency of operation, without load max. 30 operations/s
Operate / release time approx.
8/2ms
Max. DC breaking capacity (contacts Ag, gold flashed)
Curve 1: arc extinguished within contact transit period (limit curve I)
Curve 2: safe breaking, erc extinguished (limit curve II)
Contact Data (continued)
Mechanical endurance aaprox. 108 operations
1) The current of 3 A for max 4s at 10% on-time.
2) Gold F on request only
3) Self inductance in accordance with IEC 255-0-20
Coil Data
Magnetic system
Coil voltage range
Max. coil temperature
Thermal resistance
neutral, monostable
5 to 60VDC
110°C
35K/W
Coil versions, monostable
Coil
Rated
Operate Limiting
Coil
Rated coil
code
voltage
voltage
Voltage resistance power
4/6 pole
VDC
VDC
VDC
Ω±10%4)
mW
032
5
3.3/4.0
10.8
38
658
012
6
3.9/4.6
12.4
50
720
017
12
7.8/9.5
24.0
185
778
021
24
15.5/18.5 47.0
730
789
026
48
32/37
88.0
27004)
853
014
60
38/45
109.0
41004)
878
4) Coil resistance ±15%
All figures are given for coil without pre-energization, at ambient temperature +23°C
The operating voltage limits UI and UII depend on temperature according to
the following formula:
UI tamb = kI*UI 20°C, UII tu = kII*UII 20°C; tamb = ambient temperature,
UI tamb = minimum voltage at ambient temperature,
UII tamb = maximum voltage at ambient temperature, kI and kII are factors.
tamb
20°C 30°C
40°C
50°C
60°C
70°C
kI
1
1.04
1.085
1.13
1.17
1.21
kII
1
0.93
0.86
0.79
0.7
0.6
Electrical endurance
Type
Load
Ag, gold-flashed 2.4A, 24VDC, resistive
Ag, gold-flashed 3A, 24VDC, resistive
Ag, gold-flashed 1.35A, 30VDC, resistive
Ag, gold-flashed 0.85A, 40VDC, resistive
Ag, gold-flashed 0.36A, 60VDC, resistive
Ag, gold-flashed 0.21A, 110VDC, rersitive
Ag, gold-flashed 2.4A, 24VDC, resistive+100μH3)
Ag, gold-flashed 0.6A, 60VDC, resistive+100μH3)
Ag, gold-flashed 0.24A, 110VDC, resistive+100μH3)
Operations
appr. 1x106
appr. 0.3x106
appr. 6x106
appr. 2x107
appr. 8x107
appr. 10x107
appr. 1x106
appr. 10x106
40x106
Insulation Data
Initial dielectric strength
between coil and frame
between contact and contact
between contact and frame
between contact and coil
500Vrms
1000Vrms
1000Vrms
1000Vrms
07-2012, Rev. 0712
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
1
Datasheets and product data is subject to the Datasheets, product data, ‘Definitions’ sec-
terms of the disclaimer and all chapters of
tion, application notes and all specifications
the ‘Definitions’ section, available at
are subject to change.
http://relays.te.com/definitions