English
Language : 

2-1393240-5 Datasheet, PDF (1/3 Pages) Tyco Electronics – Power PCB Relay RT1 Inrush
General Purpose Relays
PCB Relays
Power PCB Relay RT1 Inrush
n 1 pole 16A, 1 form C (CO) or 1 form A (NO) contact
n For inrush peak currents up to 80A
n Mono- or bistable coil
n 5kV/10mm coil-contact
n Reinforced insulation
n Ambient temperature 85°C
SCHRACK
Typical applications
Domestic appliances, heating control, lighting control
Approvals
VDE REG.-Nr. 6106, UL E214025, cCSAus 14385
Technical data of approved types on request
Contact Data
Contact arrangement 1 form C (CO) or 1 form A (NO)
Rated voltage
250VAC
Max. switching voltage
400VAC
Rated current
16A
Limiting continuous current 16A, UL: 20A (K-version)
Limiting making current,
max. 4s, df 10%
30A
max. 20ms (incandescent lamps), RT33L version 80A
Breaking capacity max.
4000VA
Contact material
AgNi90/10, AgSnO
Frequency of operation, with/without load
360/72000h-1
Operate/release time max., DC coil
9/6ms
Operate/Reset time max., bistable version
10/10ms
Bounce time max., form A/form B
3/6ms
Contact ratings
Type
Contact
IEC 61810
RT33L A (NO)
RT33K A (NO)
UL 508
RT33K A (NO)
RT33L A (NO)
RT33L A (NO)
RT33L A (NO)
Load
Cycles
16A, 250VAC resistive, 85°C
16A, 250VAC resistive, 85°C
50x103
30x103
20A, 277VAC general purpose, 40°C
16A, 250VAC resistive, 85°C
1000W Tungsten, 120VAC, 60 Hz, 40°C
1000W standard ballast,
120VAC, 60 Hz, 40°C
10x103
50x103
6x103
6x103
Mechanical endurance
monostable version
bistable version
>30x106 operations
>5x106 operations
Zb
F0177-C
Coil Data, DC coil
Coil voltage range
Operative range, IEC 61810
Coil insulation system according UL
5 to 110VDC
2
class F
Coil versions, DC coil
Coil
Rated
Operate Release
Coil
Rated coil
code
voltage
voltage
voltage resistance power
VDC
VDC
VDC
Ω±10%1)
mW
005
5
3.5
0.5
62
403
006
6
4.2
0.6
90
400
012
12
8.4
1.2
360
400
024
24
16.8
2.4
1440
400
048
48
33.6
4.8
5520
417
060
60
42.0
6.0
85701)
420
1) Coil resistance ±12%.
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
Coil Data, bistable coils
1 coil
2 coils
Magnetic system
polarized, bistable
Coil voltage range
5 to 24VDC
Operative range, IEC 61810
2
Limiting voltage, % of rated coil voltage 120%
150%
Min./Max. energization duration 30ms/1min at <10% duty factor
Coil insulation system according UL
class F
03-2012, Rev. 0312
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
1
Datasheets and product data is subject to the Datasheets, product data, ‘Definitions’ sec-
terms of the disclaimer and all chapters of
tion, application notes and all specifications
the ‘Definitions’ section, available at
are subject to change.
http://relays.te.com/definitions