English
Language : 

2-1393237-3 Datasheet, PDF (1/3 Pages) Tyco Electronics – Power PCB Relay RT1
General Purpose Relays
PCB Relays
Power PCB Relay RT1
n 1 pole 12A/16A, 1 form C (CO) or 1 form A (NO) contact
n Sensitive coil 400mW
n 5kV/10mm coil-contact, reinforced insulation
n Ambient temperature 85°C
Potter & Brumfield
Typical applications
Boiler control, timers, garage door control, POS automation, interface
modules
VZb
Approvals
VDE REG.-Nr. 6106, UL E214025, cCSAus 14385
Technical data of approved types on request
Contact Data
12A
16A
Contact arrangement 1 form C (CO) or 1 form A (NO)
Rated voltage
250VAC
Max. switching voltage
400VAC
Rated current
12A
16A
Limiting continuous current
12A
16A, UL: 20A
Limiting making current
max. 4s, duty factor 10%
25A
30A
Breaking capacity max.
3000VA
4000VA
Contact Material
AgNi 90/10
Frequency of operation, with/without load
360/72000h-1
Operate/release time max., DC coil
8/6ms
Bounce time max., DC coil, form A/form B
4/6ms
Contact ratings
Type
Contact
Load
Cycles
IEC 61810
RT314 DC-coil A (NO)
16A, 250VAC, cosφ=1, 85°C
30x103
RT314 DC-coil C (CO)
16A, 250VAC, cosφ=1, 85°C
10x103
RT314 DC-coil A (NO)
10A, 400VAC, cosφ=1, 85°C
150x103
RT114 DC-coil A (NO)
12A, 250VAC, cosφ=1, 85°C
50x103
RT114 AC-coil A (NO)
12A, 250VAC, cosφ=1, 70°C
100x103
UL 508
RT314
A/B (NO/NC) 20A, 250VAC, general purpose, 85°C 6x103
RT334
A (NO)
16A, 250VAC, gen. purpose, 85°C 50x103
RT314
A (NO)
1hp, 240VAC, 40°C
1x103
EN60947-5-1
RT314 DC-coil A/B (NO/NC) 2A, 24VDC, DC13
6.050
EN60730-1
RT314 DC-coil A (NO)
12(2)A, 250VAC, 85°C
100x103
Contact Data (continued)
Contact ratings
Type
Load
RT3, RTD
1 HP @ 480VAC* motor
RT3, RTD
1 HP @ 240VAC* motor
RT3, RTD
1/2 HP @ 120VAC* motor
RT3, RTD
60 LRA/10 FLA @ 250VAC* motor
RT3, RTD
TV-5 @ 120VAC* Tungsten
RT3, RTD
A300, 720VA @ 240VAC* Pilot Duty
RT3, RTD
B300, 360VA @ 240VAC** Pilot Duty
*) form A (NO) contact only, **) form B (NC) contact only
Cycles
6x103
6x103
6x103
30x103
25x103
30x103
30x103
Mechanical endurance
>30x106 operations
Coil Data
Coil voltage range
Operative range, IEC 61810
Coil insulation system according UL
5 to 110VDC
2
class F
Coil versions, DC coil
Coil
Rated
Operate Release
Coil
Rated coil
code
voltage
voltage
voltage resistance power
VDC
VDC
VDC
Ω±10%
mW
005
5
3.5
0.5
62
403
006
6
4.2
0.6
90
400
009
9
6.3
0.9
200
400
012
12
8.4
1.2
360
400
024
24
16.8
2.4
1440
400
048
48
33.6
4.8
5520
417
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
04-2011, Rev. 0411
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
1
Datasheets and product data is subject to the Datasheets, product data, ‘Definitions’ sec-
terms of the disclaimer and all chapters of
tion, application notes and all specifications
the ‘Definitions’ section, available at
are subject to change.
http://relays.te.com/definitions