K10 Series Miniature Relay
n 2 Form C contact arrangement
n AC and DC coils
n Socket, PCB and top flange mounting options
Potter & Brumfield
Typical applications
Industrial controls, medical, motor controls
Approvals
UL E22575; CSA L15734
Technical data of approved types on request
Contact Data
Contact arrangement
2 form C (CO),
2 from A (NO),
2 form B (NC),
1 form A (NO) + 1 form B (NC)
Rated voltage
120VAC
Rated current
15A
Contact material Ag, AgCdO, AgSnOInO
Min. recommended contact load
Ag contacts
100mA, 12VDC
AgCdO and AgSnInO contacts
300mA, 12VDC
Initial contact resistance
100mΩ
Frequency of operation
360 ops./hour
Operate/release time max.
13/10 ms
Bounce time max.
10ms
Contact ratings
Type
Load
UL 508
Ag
10A, 30VDC
10A, 277VAC
AgCdO
15A, 120VAC
10A, 277VAC
15A, 30VDC
15 FLA, 36 LRA, 120VAC
1/3HP, 120VAC
1/2HP, 250VAC
AgSnOInO 15A, 240VAC
Mechanical endurance
Operations
10x106 operations
6x103
6x103
100x103
100x103
100x103
100x103
1x103
1x103
70x103
Coil Data
Coil voltage range
Coil insulation system according UL
6 to 110VDC
6 to 240VAC
Class B
Coil versions, DC coil
Coil
Rated
Operate Release
Coil
Rated coil
code
voltage
voltage
voltage resistance power
VDC
VDC
VDC
Ω±10%
mW
006
6
4.5
0.6
40
900
012
12
9.0
1.2
160
900
024
24
18.0
2.4
650
900
048
48
36.0
4.8
2600
900
110
110
82.5
11.0
11000
1100
All figures are given for coil without preenergization, at ambient temperature +23°C.
07-2012, Rev. 0712
www.te.com
© 2012 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Coil Data (continued)
Coil versions, AC coil
Coil
Rated
Operate Release
Coil
Rated coil
code
voltage
voltage
voltage resistance power
VAC
VAC
VAC
Ω±15%
VA
006
6
5.1
0.6
10.5
1.20
012
12
10.2
1.2
43
1.20
024
24
20.4
2.4
160
1.25
048
48
40.8
4.8
668
1.25
120
120
102.0
12.0
3900
1.35
240
240
204.0
24.0
12000
1.50
All figures are given for coil without preenergization, at ambient temperature +23°C, 60Hz.
Insulation Data
Initial dielectric strength
between open contacts
between contact and coil
between adjacent contacts
between coil and frame
Initial surge withstand voltage
between adjacent contacts
1000Vrms
1500Vrms
1500Vrms
1500Vrms
1000MΩ at 500VDC
Other Data
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
refer to the Product Compliance Support Center at
www.te.com/customersupport/rohssupportcenter
Ambient temperature
-45°C to 70°C
Category of environmental protection
IEC 61810
RT0 - open relay
RTI - dust protected
Vibration resistance (functional) .059” double amplitude, 10-55Hz,
6 hours mechanical
Shock resistance (functional) 15g. 11ms, mechanical
Terminal type quick connect (QC) .187
PCB .120” and .160” long
Weight 51g
Packaging/unit box/250 pcs., tray/50 pcs.
Accessories
For details see datasheet Sockets and Accessories, K10 Relays
Product Code Description
27E895
DIN socket
27E487
Track mount socket
20C426
Clip for 27E895 and 27E487
27E488
Chassis/solder socket
27E489
PCB socket
20C217
Clip for 27E488 and 27E489
1
Datasheets and product data is subject to the Datasheets, product data, ‘Definitions’ sec-
terms of the disclaimer and all chapters of
tion, application notes and all specifications
the ‘Definitions’ section, available at
are subject to change.
http://relays.te.com/definitions