English
Language : 

2-1393134-1 Datasheet, PDF (1/2 Pages) Tyco Electronics – Low Cost 20 Amp Industrial Relays
S86R
Mounting
Style 1
Catalog 1308242
Issued 3-03
P&B
S87R
Mounting
Style 2
S86R/S87R series
Low Cost
20 Amp
Industrial Relays
File E22575
File LR15734
Users should thoroughly review the technical data before selecting a product
part number. It is recommended that users also seek out the pertinent approvals
files of the agencies/laboratories and review them to ensure the product meets
the requirements for a given application.
Features
• Low cost.
• Contact forms to 2 Form C.
• Applications include spa controls, vending machines, HVAC, and
machine tool controls.
• Variety of mounting styles.
Contact Data @ 25°C
S86R and S87R: 20 amps @ 277VAC; 60 LRA, 12 FLA, 1 HP @
125VAC;
48 LRA, 8 FLA @ 240VAC; 2 HP @ 250VAC; Pilot
Duty,
360VA @ 125/250VAC.
Materials: Silver and silver-cadmium oxide.
Expected Life: 1 million operations, mechanical; 50,000 operations at
rated loads.
Coil Data
Nominal
Coil
Voltage
S86R &
S87R (AC)
12VAC
24VAC
120VAC
240VAC
S87R (DC)
6VDC
12VDC
24VDC
36VDC
48VDC
72VDC
125VDC
Coil Resistance (Ohms)
AC, ± 15%
DC, ± 10%
All Models
8.0
32
800
3,200
Single
Pole
Models
Double
Pole
Models
12.5
50
200
450
800
1,800
5,425
8
32
128
288
512
1,150
3,470
Nominal
Coil Current (mA)
@ 25°C*
All Models
330
165
33.0
16.5
Single
Pole
Models
Double
Pole
Models
480
750
240
375
120
188
80
125
60
94
40
63
23
36
*Increase AC current values by 25% for mounting style 2 with single switch.
Initial Dielectric Strength
Initial Breakdown Voltage: 1,560V rms, 60 Hz.
Coil Data @ 25°C
Nominal Power:
S86R: 4.0VA for AC models.
S87R: 2.9 Watts for single pole DC models.
4.5 Watts for double pole DC models.
4.0VA for AC models.
Insulation: Class B (130°C).
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Operate Data
Must Operate Voltage:
DC Coils: 75% of nominal voltage @ +25°C.
AC Coils: 85% of nominal voltage @ +25°C.
Operating Position: Relay is designed for operation with plunger either
vertical or horizontal; however, the relay is not
designed for operation in an upside-down position.
Environmental Data
Temperature Range: -10°C to +65°C.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
807
Refer to inside back cover.