2-1393115-1 Datasheet, PDF (1/3 Pages) Tyco Electronics – General Purpose Relays Industrial Relays
General Purpose Relays
Industrial Relays
KUIP/KUGP Series Panel Plug-in Relay
n 10 amp rated relays
n 2 Form A (NO) and 1-3 Form C (CO) contact arrangement
n KUIP 8mm coil-to-contact spacing and KUGP 3mm contact gap
n Various mounting and socket styles
Potter & Brumfield
Typical applications
Voltage control units
Approvals
UL E22575; CSA LR15734
Technical data of approved types on request
Contact Data
Contact arrangement
KUGP:
2 form A (NO); 3 form A (NO)
KUIP:
1 form C (CO), 2 form A (NO), 2 form C (CO), 3 form C (CO)
Rated voltage
240VAC
Rated current
10A
Contact material
Ag
AgCdO
Min recommended contact load 100mA, 12VDC 300mA, 12VDC
Frequency of operation
360 ops./hour 360 ops./hour
Operate/releases time max.
20/15ms
Bounce time max.
20ms
Contact ratings
Type
Load
UL 508
Ag
5A, 240VAC
5A, 28VDC
1/6HP, 120VAC
2.5A, 120VAC, tungsten
1/3HP, 240VAC
0.5A, 120VDC
5FLA, 15LRA, 250VAC
AgCdO
10A, 240VAC
10A, 32VDC
5FLA, 15LRA, 250VAC
1/3HP, 120VAC
5A, 120VAC, tungsten
1/2HP, 250VAC
0.5A, 125VDC
10FLA, 40LRA, 125VAC
3A, 600VAC
1/2HP, 480VAC
1/2HP, 600VAC
1HP, 480VAC, 3 phase
Mechanical endurance
10x106 ops.
Cycles
Coil Data
Coil voltage range
Coil insulation system according UL
6 to 110VDC
6 to 240VAC
Class B
Coil versions, DC coil
Coil
Rated
Operate
Coil
Rated coil
code
voltage
voltage
resistance
power
VDC
VDC
Ω±10%
W
KUIP
5
5
3.75
21
1.2
6
6
4.5
32.1
1.125
12
12
9.0
120
1.2
24
24
18.0
472
1.25
48
48
36.0
1800
1.3
110
110
82.5
10000
1.25
KUGP
5
5
3.75
14
1.8
6
6
4.5
20
1.8
12
12
9.0
80
1.8
24
24
18.0
320
1.8
48
48
36.0
1250
1.85
110
110
82.5
6720
1.8
All figures are given for coil without preenergization, at ambient temperature +23°C.
Coil versions, AC coil
Coil
Rated
Operate
code
voltage
voltage
VAC
VAC
KUIP 1 and 2 pole
6
6
5.1
12
12
10.2
24
24
20.4
120
120
102.0
240
240
204.0
KUIP 3 pole, KUGP
6
6
5.1
12
12
10.2
24
24
20.4
120
120
102.0
240
240
204.0
Coil
resistance
Ω±15%
6
24
85
2250
9110
4.2
18
72
1700
7200
Rated coil
power
VA
2.0
2.0
2.0
2.1
2.1
2.8
2.8
2.8
2.9
2.9
All figures are given for coil without preenergization, at ambient temperature +23°C.
Insulation Data
Initial dielectric strength
between open contacts
between contact and coil
between adjacent contacts
Initial insulation resistance
between insulated elements
KUIP
KUGP
1200Vrms
2200Vrms
2200Vrms
3500Vrms
3750Vrms
3750Vrms
100MΩ, 500VDC
08-2011, Rev. 0811
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
1
Datasheets and product data is subject to the Datasheets, product data, ‘Definitions’ sec-
terms of the disclaimer and all chapters of
tion, application notes and all specifications
the ‘Definitions’ section, available at
are subject to change.
http://relays.te.com/definitions