English
Language : 

2-1393092-5 Datasheet, PDF (1/3 Pages) Tyco Electronics – General Purpose Relays Industrial Relays
General Purpose Relays
Industrial Relays
Multimode Relay MT
n 2/3 pole 10A, 2 form C (CO) or 3 form C (CO) contacts
n DC and AC coils
n Mechanical indicator as standard
n Electrical indicator
n New test system with front operated finger protected
push-to-test button and integral locking test tab
n White write on panel
SCHRACK
Typical applications
Mechanical engineering, plant control
Approvals
VDE REG.-Nr. 6182, UL E214025
Technical data of approved types on request
Contact Data
Contact arrangement 2 form C (CO) or 3 form C (CO)
Rated voltage
240VAC
Max. switching voltage
400VAC
Rated current
10A
10A
4A
Limiting making current, max. 20ms 20A
20A
8A
Limiting breaking current
10A
10A
4A
Switching power
2500VA 2500VA 500 VA
Contact material
AgNi90/10 AgNi90/10 AgNi90/10
-
gold plated gold plated
Contact style
single
single bifurcated
contact
contact
contact
Min. recommended contact load
12V
20mV
20mV
at 10mA
at 1mA
at 1mA
Initial voltage drop 30mV at 100mA/6VAC/1kHz
Frequency of operation, with/without load
1200/6000h-1
Operate time max., DC coil
15ms
Release time max., DC coil
10ms
Bounce time max., DC coil, form A/form B
4/5ms
Contact ratings
Type
Contact
Load
Cycles
IEC 61810
MT22 DC coil C (CO)
10A, 250VAC, cosφ=1, 35°C
100x103
MT22 AC coil C (CO)
10A, 250VAC, cosφ=1, 35°C
20x103
MT32 DC coil C (CO)
10A, 250VAC, cosφ=1, 35°C
100x103
MT32 AC coil C (CO)
10A, 250VAC, cosφ=1, 35°C
20x103
MT2
C (CO)
10A, 250VAC, resistive, 40°
30x103
MT2
A (NO)/B (NC) B300 40°C
6.000
MT2
C (CO)
4A, 25VAC, resistive, bifurcated, 40°C 30x103
MT3
C (CO)
10A, 250VAC, resistive, 40°C
30x103
UL 508
MT3
A (NO)/B (NC) B300, 40°C
6.000
MT3
C (CO)
4A, 25VAC, resistive, bifurcated, 40°C 30x103
Contact Data (continued)
Mechanical endurance
DC coil
AC coil
F0161-B
VZ
20x106 operations
20x106 operations
Coil Data
Coil voltage range
6 to 220VDC
6 to 230VAC
Operative range, IEC 61810
2
Coil insulation system according UL
class 130 (B)
Coil versions, DC coil
Coil code
Rated Operate Release
Coil Rated coil
STD PD3) voltage voltage voltage resistance power
VDC
VDC
VDC Ω±10%1)2)
W
006 0A6
6
4.5
0.6
32
1.1
012 0B2
12
9.0
1.2
110
1.3
024 0C4
24
18.0
2.4
475
1.2
048 0E8
48
36.0
4.8
2000
1.2
060 0G0
60
45.0
6.0
2850
1.3
110 1B0
110
82.5
11.5
100001)
1.2
220 2C0
220
165.0
22.0
400002)
1.2
1) Coil resistance ±12%, 2) Coil resistance ±15%
3) Protection diode PD; standard polarity: 2-pole relays: +2 / -7, 3-pole relays: +2 / -10
All figures are given for coil without pre-energization, at ambient temperature +23°C
Coil versions, AC coil, 50/60Hz
Coil
Rated
Operate Release
Coil
code
voltage
voltage
voltage resistance
50/60Hz 50/60Hz
VAC
VAC
VAC
Ω±10%1)
006
6
4.8/5.1
1.8
5.3
012
12
9.6/10.2
3.6
24
024
24
19.2/20.4
7.2
86
048
48
38.4/40.8 14.4
345
060
60
48.0/51.0 18.0
544
115
115
92.0/97.8 34.5
2000
230
230 184.0/195.5 69.0
83001)
Rated coil
power
50/60Hz
VA
2.29/1.98
2.19/1.86
2.26/1.95
2.28/1.97
2.27/1.96
2.37/2.00
2.32/1.96
1) Coil resistance ±12%
All figures are given for coil without pre-energization, at ambient temperature +23°C
04-2011, Rev. 0411
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
1
Datasheets and product data is subject to the Datasheets, product data, ‘Definitions’ sec-
terms of the disclaimer and all chapters of
tion, application notes and all specifications
the ‘Definitions’ section, available at
are subject to change.
http://relays.te.com/definitions