English
Language : 

15DCF6_1 Datasheet, PDF (1/4 Pages) Tyco Electronics – RFI Power Line Filters for DC Applications
DC Series
CORCOM Product Guide
RFI Power Line Filters for DC Applications
EN
60 950
UL Recognized
CSA Certified
TUV Approved
DC
Specifications
Hipot rating (one minute):
DC Series
The DC series filters were designed as general purpose line filters
for DC applications. They are available with or without circuit
breakers for extra protection. They are available with feed-through
capacitors for added high frequency performance. The DC series
is designed to comply with UL 1283, CSA 22.2 No. 8 and
EN60950.
The DC series was developed in response to the increasing
demand for DC filtering in the telecom-datacom market. These
filters are generally used in central office equipment like switches,
routers, and hubs to clean up the 48 VDC power, but are not
exclusive to that equipment. They can also be used at the primary
input of the DC power supply. The DC Series is available in both a
flange mount (DCF) and bulkhead mount (DCB) configuration.
Circuit Breaker Features (B Suffix)
• always hold 100% of rated current independent of ambient
temperature (minimize nuisance tripping)
• Always trip at 125% of rated current independent of ambient
temperature
• Can be combined with feed through capacitor in bulk head
mount (DCB prefix) for high performance applications (BF
Suffix)
Feed Through Capacitor for High Performance (F Suffix)
• High performance results out to 3Ghz
• Available only in bulk head (DCB prefix ) configuration only
• Can be combined with circuit breaker feature (BF Suffix)
line-to-ground
line-to-line
Operating Voltage (max):
2250 VDC
1450 VDC
80 VDC
Operating Ambient Temperature Range:
(@ rated current Ir)
-10˚C to +55˚C
In an ambient, Ta, higher than +55˚C, the maximum
operating current, Io, is as follows: Io = Ir
85 - Ta
30
Minimum insertion loss in dB:
Standard Performance
Line-to-ground in 50 ohm circuit
Current
Frequency-MHz
Rating .01 .05 .1 .15 .5 1 3 5 10 30
15A - 1 12 20 41 45 61 63 47 39
30A - 4 15 23 47 59 64 56 44 36
60A - - 9 17 38 40 59 50 39 34
100A - - 10 18 38 39 53 50 35 21
125A - - 12 18 30 32 44 49 29 18
Line-to-line in 50 ohm circuit
Current
Frequency-MHz
Rating .01 .05 .1 .15 .5 1 3 5 10 30
15A 7 22 27 30 30 36 56 49 38 31
30A 7 22 28 31 32 59 56 51 41 28
60A 15 30 36 40 40 35 60 51 39 32
100A 14 29 35 39 33 30 53 53 41 30
125A 14 24 35 39 40 28 53 60 42 33
Electrical Schematics
Standard Performance Version
LINE
Note 2
Note 3
Note 1
LOAD
Note 1
Note 4
High Frequency Performance Version
LINE
Note 2
LOAD
Note 3
Note 1
Note 4
Resistor location for reference only.
Note 1: Depicts redundant style 6 terminals.
Note 2: Depicts optional circuit breaker.
Note 3: For 100 & 125A versions delete second coil.
150 Note 4: Depicts style 10 terminal versions which have separate ground stud.
High Frequency Performance ("F" & "BF" Styles)
Line-to-ground in 50 ohm circuit
Current
Frequency-MHz
50 300
to to
Rating .01 .05 .1 .15 .5 1 3 5 10 20 300 3000
15A - 1 12 20 41 45 55 50 45 25 50 30
30A - 4 15 20 46 58 60 60 48 35 50 30
60A - - 9 16 38 42 52 60 48 26 40 30
100A - - 9 16 38 42 52 60 42 26 40 30
125A - - 9 16 28 34 46 54 34 34 40 30
Line-to-line in 50 ohm circuit
Current
Frequency-MHz
Rating .01 .05 .1 .15 .5 1 3 5 10 20
15A 7 22 27 30 30 50 60 60 60 36
30A 7 22 27 30 33 56 60 60 60 40
60A 15 30 36 40 37 26 46 54 48 30
100A 14 29 35 39 33 30 56 53 41 30
125A 14 29 35 39 40 28 53 60 42 33
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
www.corcom.com
www.tycoelectronics.com