English
Language : 

1375055-7 Datasheet, PDF (1/11 Pages) Tyco Electronics – SL Series Jacks, Category 6
Product
Specification
SL Series Jacks, Category 6
108-131000
7 June 13 Rev B
1. SCOPE
1.1 Content
This specification covers performance, tests and quality requirements for AMP NETCONNECT*,
Category 6 SL Jacks used to provide a universal connection interface between premise wiring of an office
and the user's network of communications equipment (for data and voice networking systems). These
assemblies are designed for installation into various outlet plates, surface mount boxes, panels and other
similar type fittings. Jacks incorporate IDC terminals for terminating unshielded twisted pair
communications cable. Jacks will accommodate:
Solid conductor cable range
(AWG)
22 - 24
Stranded conductor cable
range (AWG)
24 - 26
Max. conductor insulation
diameter (mm [in])
1.45 [0.057]
Max. cable jacket outer
diameter (mm [in])
5.8 [0.23]
1.2 Qualification
When tests are performed on the subject product line, procedures specified in Figure 1 shall be used. All
inspections shall be performed using the applicable inspection plan and product drawing.
2. APPLICABLE DOCUMENTS
The following documents form a part of this specification to the extent specified herein. Unless otherwise
specified, the latest edition of the document applies. In the event of conflict between the requirements of
this specification and the product drawing, the product drawing shall take precedence. In the event of
conflict between the requirements of this specification and the referenced documents, this specification
shall take precedence.
2.1 TE Connectivity (TE) Documents
 408-8417: Instruction Sheet (SL, KL and Secure SL Series 110Connect Modular Jacks)
 408-8858: Instruction Sheet (SL Jack Tool Kit 1725150-X)
 501-131000: Qualification Test Report (SL Series Jacks, Category 6) Revision A – covers assemblies
utilizing component engine 2111323
 501-131000: Qualification Test Report (SL Series Jacks, Category 6) Revision B – covers assemblies
utilizing component engine 2111621
2.2 Industry Documents
 ANSI/TIA-568-C.2 April 2010: Balanced Twisted-Pair Telecommunications Cabling and Components
Standards
 IEC 60068: Basic Environmental Testing Procedures as indicated in Figure 1
 IEC 60352-4 Amendment 1 2000-07: Non-Accessible Insulation Displacement Connections – General
Requirements, Test Methods and Practical Guidance
 IEC 60512: Basic Testing Procedures and Measuring Methods for Electromechanical Components for
Electronic Equipment as indicated in Figure 1
©2013 Tyco Electronics Corporation, a TE Connectivity Ltd. Company
All Rights Reserved
| Indicates Change
This controlled document is subject to change.
For latest revision and Regional Customer Service, visit our website at www.te.com
PRODUCT INFORMATION 1-800-522-6752
1 of 11
*Trademark. AMP NETCONNECT, TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product and/or Company names may be trademarks of their
respective owners.