1350-2A-100.0 Datasheet, PDF (1/1 Pages) Tyco Electronics – AC Voltage Level Sensor, Relay Output
1350 Series
AC Voltage Level Sensor, Relay Output
Product Facts
I Standard models combine AC
(400 Hz.) voltage-sensing
circuit with 2A DPDT output
relay.
I Various applications
I Motor protection
I Ground support equipment
I Low or high line alarms
I Computer protection
I Many customizing options
I Solid state output
I Two-stage sensing
(voltage band)
I Up to 10A relay output
I 3 phase version
I Controlled dropout
differential
I Operate with auxiliary
control voltage
I Under and over voltage trip
I Time delay on trip point
I Tighter accuracy
I Lower trip points
I Different package,
mounting, header
I 60 Hz. versions
Electrical Specifications
Pull-In Voltage: Any voltage level
between 50 to 150Vac, 400 Hz., in 1.0
volt increments.
Drop-Out Voltage: 0 to 3.0V max,
(1.5V nom.) below pull-in voltage.
Current Drain: 100mA max @ 25°C.
Accuracy: ±2.5% of set point over
temperature range.
Max. Allowable Applied Voltage:
150% of specified pull-in voltage.
Auxiliary Voltage: None required.
Operate and Release Times: 50ms
max. over the temperature range.
The CII 1350 series AC voltage
sensor energizes a relay when
the monitored power line
voltage reaches a
predetermined level. This
rugged unit with reliable solid-
state design provides precise,
repeatable operation over a
wide temperature range. The
input voltage is fed into a
temperature compensated
comparator circuit. When the
input reaches the preset level,
transistor amplifiers switch the
output relay. This output may
control any external devices,
Outline Dimensions
.06[13.6M0A]X.[9.3.5735]
#4-40 THD
4 PLACES
2.0 MAX.
[50.8]
2.0 MAX.
[50.8]
.375
[9.53]
INDEX DOT
1.00 MAX.
[25.4]
.625
[15.875]
.875
1.25 MAX. [22.22]
[31.75]
.063 MAX.
[1.60]
#4-40 THD
4 PLACES
.75 DIA.
[19.05]
MAX.
.250
[6.35]
INDEX DOT
1.00 MAX.
[25.4]
.625
[15.875]
.875
1.25 MAX. [22.22]
[31.75]
process or warning system to
protect expensive equipment.
The unit is potted and
hermetically sealed and is
designed to meet the
environmental requirements of
MIL-R-83726.
.625
[15.875]
2.0 MAX.
[50.8]
.625
[15.875]
1.25
[31.75]
.250
[6.35]
.375
[9.53]
.063 MAX.
[1.60]
1.00 MAX.
[25.4]
#4-40 THD
4 PLACES
INDEX
DOT
1.25 MAX.
[31.75]
Contact Arrangement: 2 Form C
(DPDT).
Mounting Option A
Mounting Option B
Mounting Option C
Contact Rating:
2 amps resistive @30Vdc
300mA resistive @ 115 Vrms, 400 Hz.
Environmental Specifications Wiring Diagram
Part Numbering System
Temperature Range: -55°C to
+125°C.
INPUT
Vibration: 20’G,s, 10 - 2,000 Hz.
Shock: 50 G’s, 11 ± 1ms duration.
INDEX DOT
Insulation Resistance: 1,000
megohms, min., at 500Vdc, all terminals
to case.
Dielectric Strength: 1,000Vrms, 60
Hz., at sea level, all terminals to case.
Typical Part Number
1350 - 2
Series:
1350 = AC Voltage Level Sensor, Relay Output
Contact Form:
2 = 2 Form C (DPDT)
Mounting (see outline dimension drawings):
A = Studs on bottom B = Studs on top C = Studs on side
Pull-In Voltage:
Specify any level between 50 and 150Vac in 1.0 volt increments
A - 100.0
Sealing: Hermetic, 1.3 in. (33.0mm) of
mercury.
Life: 100,000 operations, min.
Weight: 3.5 oz (99.2g) max.
© 2006 by Tyco Electronics Corporation. All Rights Reserved.
CII and TYCO are trademarks.
Other products and company names mentioned herein may be trademarks of their respective owners.
1
Catalog 7-1773439-5
Revised 1-06
www.tycoelectronics.com
Dimensions are in inches and
millimeters unless otherwise
specified. Values in brackets
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-5-729-0425
South America: 55-11-3611-1514
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
UK: 44-141-810-8967