English
Language : 

03EQ1 Datasheet, PDF (1/2 Pages) Tyco Electronics – Highest Performance RFI Filters for Switching Power Supply Emissions down to 10 kHz
Q Series
CORCOM Product Guide
Highest Performance RFI Filters for Switching Power Supply
Emissions down to 10 kHz
UL Recognized
CSA Certified
VDE Approved
Q8-6A
Q1
Q3
Q Series
This series of RFI power line filters has been developed
specifically for switching power supplies and is designed to
be all the power line filtering needed to control conducted
emissions all the way down to 10kHz. High attenuation is
provided for both common mode and differential mode
interference throughout the frequency range with no
degradation of performance due to the large peak currents
drawn by switching power supplies.
These filters are an ideal choice for applications that must
meet emission limits below 150kHz, as well as the
mandated limits above 150kHz. In most cases they will
bring such equipment into compliance with the B-level
limits of CISPR 22. They are also well suited for bringing
ISM equipment (such as ultrasonic cleaners) into
compliance with the limits of FCC Part 18, from 10kHz to
30MHz.
The EQ models meet the very low leakage current
requirements VDE portable equipment, and (120 Volt)
UL544 non-patient medical equipment. The VQ models
offer higher common mode performance at the expense of
higher leakage current, but still meet the leakage current
limits of UL, CSA, and VDE non-portable equipment.
Electrical Schematics
3EQ & 3VQ Models
Specifications
Maximum leakage current,each line-to-ground
VQ Models EQ Models
@ 120 VAC 60 Hz (3A, 20A): .73 mA .22 mA
@ 120 VAC 60 Hz (6A):
—
.29 mA
@ 250 VAC 50 Hz (3A, 20A): 1.27 mA .38 mA
@ 250 VAC 50 Hz (6A):
—
.51 mA
Hipot rating (one minute):
line-to-ground
2250 VDC
line-to-line
1450 VDC
Operating frequency:
50/60 Hz
Rated voltage (max.):
250 VAC
Rated current:
3VQ/3EQ
3A
6EQ
6A
20EQ1/20VQ1
20A
Minimum insertion loss in dB:
Line-to-ground in 50 ohm circuit
Current
Frequency–MHz
Rating .01 .02 .05 .15 .5 1 5 10 30
3VQ
3EQ
6EQ
20EQ1
20VQ1
22 27 37 50 55 55 55 50 55
22 27 36 47 47 43 45 45 45
26 31 20 68 72 72 65 65 65
6 10 8 39 60 65 65 65 55
6 3 17 52 65 70 70 70 70
LINE
6EQ & 20EQ Models
LINE
LOAD
LOAD
Line-to-line in 50 ohm circuit
Current
Frequency–MHz
Rating .01 .02 .05 .15 .5 1 5 10 30
3VQ
3EQ
6EQ
20EQ1
20VQ1
1 17 42 65 75 75 60 65 65
1 17 42 65 75 75 65 65 60
6 10 43 70 75 75 65 55 55
15 20 20 46 65 70 65 60 60
15 20 20 46 65 70 65 60 60
Resistor location for reference only.
76
Catalog 1654001
Revised 03-04
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Line Cord
Line Cord No. GA400: 7 1/2 foot, 3-conductor line cord
to mate with Q8 models.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
1-508-992-4495
Germany:
49-89-6089-0
www.cor.com
www.tycoelectronics.com