English
Language : 

MAFL-009478-CD0AC0 Datasheet, PDF (3/4 Pages) M/A-COM Technology Solutions, Inc. – RoHS Compliant
MAFL-009478-CD0AC0
CATV Diplex Filter
50 - 870 / 950 - 1550 / 2000 - 3000 MHz
Electrical Specifications: TA = 25°C, Z0 = 75Ω 1
Parameter
Frequency Range
Test Conditions
50 - 870 / 950 - 1550 / 2000 - 3000
Common to Low
Insertion Loss
Common to Low
Stop band Rejection
50 - 870MHz
950 - 975MHz
975 - 1055 MHz
1055 - 1550MHz
1790 - 2100MHz
M/A-COM Products
Rev. V1
Units Min Typ Max
MHz
dB
-
1.5
2.5
dB
30
37
-
dB
35
40
-
dB
40
45
-
dB
20
30
-
Common to High
Stop band Rejection
Common to High
Insertion Loss
Common to High
Stop band Rejection
50 - 860MHz
860 - 870MHz
950 - 1125MHz
1125 - 1550MHz
2000 - 3000MHz
dB
40
44
-
dB
37.5
39
-
dB
-
2.0
2.75
dB
-
1.0
2.0
dB
17.5
22
-
Common Port
Return Loss
50 - 300MHz
300 - 600MHz
600 - 870MHz
950 - 1400MHz
1400 - 1550MHz
dB
16
25
-
dB
14
18
-
dB
12
14
-
dB
14
20
-
dB
10
12
-
3
ADVANCED: Data Sheets contain information regarding a product M/A-COM is considering for
• North America Tel: 800.366.2266 / Fax: 978.366.2266
development. Performance is based on target specifications, simulated results, and/or prototype
measurements. Commitment to develop is not guaranteed.
PRELIMINARY: Data Sheets contain information regarding a product M/A-COM has under develop-
ment. Performance is based on engineering tests. Specifications are typical. Mechanical outline has
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
been fixed. Engineering samples and/or test data may be available. Commitment to produce in
volume is not guaranteed.
M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or
information contained herein without notice.