MACP-010563 Datasheet, PDF (3/5 Pages) M/A-COM Technology Solutions, Inc. – Temperature Compensated Directional RMS Power Detector
MACP-010563
Temperature Compensated Directional RMS Power Detector
10 - 30 GHz
Rev. V1
Application Information
The MACP-010563 is designed to deliver high
performance and to be easy to use.
No external components are needed. The RF
connections required by the MACP-010563 are
shown in a schematic below.
Recommended PCB Configuration
RF Input
(Pin 1)
MACP‐010563
RF Output
(Pin 6)
RF Ground
Pin 1 should be connected to the RF line bringing
the input signal. Pin 6 is the RF output. The third
required connection is that to the RF ground. The
exposed metal paddle on the back of the package
must be connected to the RF ground of the board
housing the detector. This can be accomplished by
using conductive via holes. It is important to ensure
that the parasitic inductance associated with the
connection between the detector and the RF ground
is as small as possible. The RF ground also provides
the return path for the DC bias current.
DC Bias
The MACP-010563 operates with a positive 3.2 V
bias applied to Pin 3. The output voltage is available
on Pin 4.
Evaluation Board
MA-COM Technology Solutions’ will supply an
evaluation board and loose samples upon qualified
request. The kit consists of a PCB and SMA
connectors. MA-COM Technology Solutions’
suggests a Rogers 4350 dielectric of .008” (0.20
mm) with ½ ounce copper. Proper grounding is
always important, we suggest 8 mil (0.20 mm) vias
placed generously underneath the part.
3
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298