English
Language : 

SW-442 Datasheet, PDF (2/4 Pages) Tyco Electronics – GaAs SPDT Terminated Switch DC - 3.0 GHz
SW-442
GaAs SPDT Terminated Switch
DC - 3.0 GHz
Rev. V4
Electrical Specifications: TA = 25°C, Z0 = 50 Ω 3, VCTL = -3V (unless otherwise specified)
Parameter
Test Conditions
Units Min. Typ. Max.
Insertion Loss4
DC-1 GHz
1-2 GHz
2-3 GHz
dB
—
0.5
0.7
dB
—
0.8
1.0
dB
—
1.1
1.25
Isolation
DC-1 GHz
1-2 GHz
2-3 GHz
dB
36
38
—
dB
25
28
—
dB
21
22
—
VSWR
DC-2 GHz
2-3 GHz
Ratio
—
1.4:1 1.5:1
Ratio
—
1.6:1 1.7:1
P1dB (2.7 V supply)
500 MHz - 3 GHz
dBm
—
24
—
P1dB (5 V supply)
500 MHz - 3 GHz
dBm
—
28
—
IP2 (2.7 V supply)
2-Tone 900 MHz, 5 MHz spacing, 10 dBm each tone dBm
—
80
—
IP3 (2.7 V supply)
2-Tone 900 MHz, 5 MHz spacing, 10 dBm each tone dBm
—
50
—
Trise, Tfall
Ton, Toff
Transients
10% to 90% RF, 90% to 10% RF
50% Control to 90% RF, 50% Control to 10% RF
In-Band
nS
—
40
—
nS
—
60
—
mV
—
10
—
Control Current
VCTL = -3V
µA
—
6
15
3. External DC blocking capacitors are required on all RF ports when using positive voltage control.
4. Insertion loss can be optimized by varying the DC blocking capacitor value, e.g. 1000 pF for 100 MHz - 1 GHz, 39 pF for 0.5 GHz - 3 GHz.
Absolute Maximum Ratings 5,6
Parameter
Absolute Maximum
Input Power (0.5 - 3.0 GHz)
3 V Control
5 V Control
+30 dBm
+33 dBm
Operating Voltage
+8.5 Volts
Operating Temperature
-40°C to +85°C
Storage Temperature
-65°C to +150°C
5. Exceeding any one or combination of these limits may cause
permanent damage to this device.
6. M/A-COM does not recommend sustained operation near
these survivability limits.
Truth Table
Mode
(Control)
V1
V2
RFC -
RF1
RFC -
RF2
Positive7
0 + 0.2 V
+2.5 to +8
V
+2.5 to +8
V
0 + 0.2 V
On
Off
Off
On
Negative8
0 + 0.2 V
-2.5 to -8 V
-2.5 to -8 V
0 + 0.2 V
Off
On
On
Off
7. External DC blocking capacitors are required on all RF ports
and GND. GND capacitors can be used with positive control
voltage to resonate lead inductance for improved isolation.
8. If negative control is used, DC blocking capacitors and GND
capacitors are not required.
2
ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions • North America Tel: 800.366.2266 / Fax: 978.366.2266
is considering for development. Performance is based on target specifications, simulated results,
and/or prototype measurements. Commitment to develop is not guaranteed.
PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology
Solutions has under development. Performance is based on engineering tests. Specifications are
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macomtech.com for additional data sheets and product information.
typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available. M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make
Commitment to produce in volume is not guaranteed.
changes to the product(s) or information contained herein without notice.