MACP-010562 Datasheet, PDF (2/5 Pages) M/A-COM Technology Solutions, Inc. – Temperature Compensated Directional RMS Power Detector
MACP-010562
Temperature Compensated Directional RMS Power Detector
6 - 18 GHz
Electrical Specifications:
Freq. = 12 GHz, TA = 25°C, VB = +3.2 V, Z0 = 50 Ω (unless otherwise specified)
Parameter
Insertion Loss
Detect Voltage
Directivity
Sensitivity
Maximum Power
Input Return Loss
Output Return Loss
DC Offset
Bias Current
Test Conditions
6 GHz
12 GHz
18 GHz
10 dBm applied to Input
6 GHz
12 GHz
18 GHz
Into 50 Ω load
6 GHz
12 GHz
18 GHz
Minimum recommended power level
6 GHz
12 GHz
18 GHz
Maximum recommended power level
6 - 18 GHz
6 - 18 GHz
6 - 18 GHz
Detect voltage with no RF input power
V Bias = 3.2 V
Units
dB
mV
dB
dBm
dBm
dB
dB
mV
mA
Min.
—
—
—
—
—
—
—
50
—
Typ.
0.15
0.3
0.55
195
375
615
17
19
12
-11
-17
-21
30
18
20
100
0.3
Rev. V1
Max.
—
—
—
—
—
—
—
150
0.35
Absolute Maximum Ratings 4,5
Parameter
Absolute Maximum
Input Power
+40 dBm
Operating Voltage
8V
Operating Temperature
-40°C to +85°C
Storage Temperature
-65°C to +150°C
4. Exceeding any one or combination of these limits may cause
permanent damage to this device.
5. M/A-COM Technology Solutions does not recommend
sustained operation near these survivability limits.
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive
to electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
devices.
2
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298