English
Language : 

MAAM-009778 Datasheet, PDF (2/8 Pages) M/A-COM Technology Solutions, Inc. – Broadband CATV 4-Way Active Splitter with Default Loop-Through
MAAM-009778
Broadband CATV 4-Way Active Splitter with Default Loop-Through
Switch 50 - 1100 MHz
Electrical Specifications4: Freq. = 1000 MHz, TA = 25°C, Z0 = 75 Ω
Parameter
Gain
Test Conditions
In to Out1, 2, or 3
In to Out4
VDD (V) VC (V) Units
5
3.3 dB
Min.
2
1.8
Insertion Loss
Noise Figure
Gain Flatness
Input Return Loss
Input Return Loss
Output Return Loss
Output Return Loss
Out to Out Isolation
Out to Out Isolation
In to Out4
In to Out1, 2, 3, or 4
In to Out1, 2, 3, or 4
Input
Input
Output
Output
Out1 to Out2, 3 or 4
Out1 to Out2 or 3
0
0
dB
-
5
3.3 dB
-
5
3.3 dB
-
5
3.3 dB
-
0
0
dB
-
5
3.3 dB
-
0
0
dB
-
5
3.3 dB
-
0
0
dB
-
CTB
132 Channels, +15 dBmV/Channel
at the input
5
3.3 dBc
-
CSO
132 Channels, +15 dBmV/Channel
at the input
5
3.3 dBc
-
Reverse Isolation
Reverse Isolation
Reverse Isolation
OIP2
OIP3
Out1, 2, 3 to In
5
3.3 dB
-
Out4 to In
5
3.3 dB
-
Out1, 2, 3 to In
0
0
dB
-
500 MHz, 2-tone,
6 MHz spacing, -10 dBm Pout
5
3.3/0 dBm
-
500 MHz, 2-tone,
6 MHz spacing, -10 dBm Pout
5
3.3/0 dBm
-
P1dB
P1dB
500 MHz
500 MHz
5
3.3 dBm
-
5
0 dBm
-
IDD
5
3.3 mA
-
IC
5
3.3 µA
-
4. The unpowered state is the same as VC = 0V
Rev. V1
Typ.
2.5
2.5
0.75
4.5
0.8
12
12
10
10
22
35
-65
-60
31
23
45
42
22
6
25
100
230
Max.
4.5
4.5
1.0
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
130
250
2
ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions • North America Tel: 800.366.2266 • Europe Tel: +353.21.244.6400
is considering for development. Performance is based on target specifications, simulated results,
and/or prototype measurements. Commitment to develop is not guaranteed.
PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology
• India Tel: +91.80.43537383
• China Tel: +86.21.2407.1588
Visit www.macomtech.com for additional data sheets and product information.
Solutions has under development. Performance is based on engineering tests. Specifications are
typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available. M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make
Commitment to produce in volume is not guaranteed.
changes to the product(s) or information contained herein without notice.