English
Language : 

MAAM-008822_15 Datasheet, PDF (2/8 Pages) M/A-COM Technology Solutions, Inc. – Broadband CATV Single Ended 3-Way Active Splitter
MAAM-008822
Broadband CATV Single Ended 3-Way Active Splitter
50 - 1100 MHz
Electrical Specifications: Freq. = 1000 MHz, TA = 25°C, VDD = +5 Volts, Z0 = 75 Ω
Parameter
Test Conditions
Units Min.
Typ.
Gain
IN to OUT1
IN to OUT2, IN to OUT3
dB
1
3
1.3
4.5
Gain Flatness
IN to OUT1, IN to OUT2, IN to OUT3
dB
-
0.5
Noise Figure
IN to OUT1
IN to OUT2; IN to OUT3
dB
-
-
4.5
4.0
Input Return Loss
IN
dB
-
16
Output Return Loss
OUT1
OUT2, OUT3
dB
-
-
8
19
Composite Triple Beat, CTB
132 channels, +15 dBmV/channel at the input
All Outputs
dBc
-
-63
Composite Second Order, CSO
132 channels, +15 dBmV/channel at the input
All Outputs
dBc
-
-60
Reverse Isolation
OUT1 to IN
OUT2 to IN, OUT3 to IN
dB
-
-
-30
-27
Output to Output Isolation
OUT1 to OUT2; OUT1 to OUT3
OUT2 to OUT3
dB
-
-
21
18
Output Power at 1dB Compression,
P1dB
OUT1
OUT2, OUT3
dBm
-
-
7.5
11
Output 3rd Order Intercept Point,
OIP3
500 MHz, 2-tone, 6 MHz spacing, -15 dBm Pout
OUT1
OUT2, OUT3
dBm
-
-
23
24
Output 2nd Order Intercept Point,
OIP2
500 MHz, 2-tone, 6 MHz spacing, -15 dBm Pout
OUT1
OUT2, OUT3
dBm
-
-
45
48
IDD
VDD= +5 Volts
mA
-
120
Rev. V1
Max.
3
5.5
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
150
Absolute Maximum Ratings 4,5,6,7
Parameter
Absolute Maximum
Max Input Power
+12 dBm
Vbias
+10.0 V
Operating Temperature
-20°C to +85°C
Junction Temperature
150°C
Storage Temperature
-65°C to +150°C
4. Exceeding any one or combination of these limits may cause
permanent damage to this device.
5. M/A-COM does not recommend sustained operation near these
survivability limits.
6. These operating conditions will ensure MTTF > 1 x 106 hours.
7. Junction Temperature (TJ) = TC + Ó¨jc * ((V * I) - (POUT - PIN))
Typical thermal resistance (Өjc) = 77° C/W.
a) For TC = 25°C,
TJ = 71 °C @ 5 V, 120 mA
b) For TC = 85°C,
TJ = 127 °C @ 5 V, 110 mA
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive
to electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
devices.
2
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.