English
Language : 

MA4EX600M-1225T Datasheet, PDF (2/2 Pages) Tyco Electronics – Silicon Double Balanced HMICTM Mixer, 4200 - 6000 MHz
MA4EX600M-1225T
Silicon Double Balanced HMIC Mixer
4200 – 6000 MHz
Rev. V1
Typical Performance Curves ( LO Drive = +10 dbm, RF = -10 dBm, IF = 60 MHz )
CONVERSION LOSS
5
5.5
PLO = 13dBm
6
PLO = 10dBm
6.5
7
7.5
PLO = 7dBm
8
8.5
9
4200 4300 4400 4500 4600 4700 4800 4900 5000 5100 5200 5300 5400 5500 5600 5700 5800 5900 6000
FREQUENCY (MHz)
VSWR
IF FREQUENCY (MHz)
50 150 250 350 450 550 650 750 850 950 1050 1150 1250 1350 1450 1550 1650 1750 1850 1950
2.80
2.60
LO Port
2.40
2.20
2.00
1.80
IF
1.60
1.40
RF Port
1.20
1.00
4200 4300 4400 4500 4600 4700 4800 4900 5000 5100 5200 5300 5400 5500 5600 5700 5800 5900 6000
RF & LO FREQUENCY (MHz)
Case Style – SOT- 25
ISOLATION
0
-5
R-I
-10
-15
L-I
-20
-25
L-R
-30
4200 4300 4400 4500 4600 4700 4800 4900 5000 5100 5200 5300 5400 5500 5600 5700 5800 5900 6000
RF FREQUENCY (MHz)
INPUT IP3 & 1dB Compression Power
18
PLO = 13dBm
16
PLO = 10dBm
14
12
10
PLO = 7dBm
8
6
1db Compression Pt.
4
2
0
4200 4300 4400 4500 4600 4700 4800 4900 5000 5100 5200 5300 5400 5500 5600 5700 5800 5900 6000
FREQUENCY (MHz)
Schematic
IF
RF
LO
INCHES
MILLIMETERS
DIM
MIN
MAX
MIN
MAX
A
.106
.122
2.70
3.10
B
.100
.118
2.54
3.00
C
⎯
.051
⎯
1.30
D
.063 REF.
1.60 REF.
E
.032
.043
.80
1.10
F
.014
.020
.35
.50
G
.003
⎯
.08
⎯
H
.000
.006
.00
.15
J
.018 REF.
.45 REF
Notes: 1. Leads Coplanarity should be 0.003 (0.08) max.
2
Absolute Maximum Ratings1
Parameter
Maximum Ratings
Operating Temperature
Storage Temperature
Incident LO Power
Incident RF Power
-40 °C to +85 °C
-65 °C to +150 °C
+ 20 dBm C.W.
+ 20 dBm C.W.
1. Exceeding these limits may cause permanent damage.
ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology
Solutions is considering for development. Performance is based on target specifications,
simulated results, and/or prototype measurements. Commitment to develop is not guaranteed.
PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology
Solutions has under development. Performance is based on engineering tests. Specifications
are typical. Mechanical outline has been fixed. Engineering samples and/or test data may be
available. Commitment to produce in volume is not guaranteed.
• North America Tel: 800.366.2266 • Europe Tel: +353.21.244.6400
• India Tel: +91.80.43537383
• China Tel: +86.21.2407.1588
Visit www.macomtech.com for additional data sheets and product information.
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make
changes to the product(s) or information contained herein without notice.