English
Language : 

MAFL-010609 Datasheet, PDF (1/7 Pages) M/A-COM Technology Solutions, Inc. – MACOM Technology Solutions MAFL-010609
MAFL-010609
Satellite Triplex Filter
950 - 1450 / 1650 - 2150 / 2500 - 3000 MHz
Description
 MACOM Technology Solutions MAFL-010609 is a
surface mount triplex filter unit designed for Satellite
applications.
Features
 75 Ohm
 SMT unit
 RoHS* Compliant
 SAT1 BPF 950-1450 MHz
 SAT2 BPF 1650-2150 MHz
 SAT3 BPF 2500-3000 MHz
Functional Schematic
Rev. V3
Electrical Specifications: TA = 25°C, Z0 = 75
Parameter
Units Min Typ Max
Parameter
Units Min Typ Max
SAT1 Band
Insertion Loss
950 - 1450 MHz
Rejection
500 - 875 MHz
1550 MHz
1630 - 2150 MHz
2400 - 4500 MHz
SAT2 Band
Insertion Loss
1650 - 2150 MHz
Rejection
500 - 1470 MHz
1550 MHz
2400 - 2420 MHz
2420 - 2440 MHz
2440 - 4500 MHz
SAT3 Band
Insertion Loss
2500 - 3000 MHz
Rejection
500 - 875 MHz
950 - 2230 MHz
2230 - 2240 MHz
2240 - 2250 MHz
3500 - 4500 MHz
Return Loss
Common Port
950 - 1450MHz
1650 - 2150 MHz
2500 - 3000 MHz
SAT1 Port
950 - 1450 MHz
SAT 2 Port
1650 - 2150 MHz
SAT 3 Port
2500 - 3000 MHz
Isolation
dB
-
1.5
3.0
SAT1 - SAT2 / SAT2 - SAT1
950 - 1450 MHz
dB
30
-
1650 - 2150 MHz
dB
9
15
-
dB
30
40
-
SAT1 - SAT3 / SAT3 - SAT1
dB
35
45
-
950 - 1450 MHz
2500 - 3000 MHz
dB
36
45
-
dB
30
35
-
dB
37
45
-
dB
35
43
-
SAT2 - SAT3 / SAT3 - SAT2
dB
-
2.0
3.0
dB
36
45
-
1650 - 2150 MHz
2500 - 3000 MHz
dB
37
45
-
dB
35
43
-
dB
9
15
-
dB
27
40
-
dB
31
40
-
Parameter
Pass Band Flatness
Units Max
dB
35
45
-
P-P over the band
SAT1 / SAT2 /SAT3
dB
3
dB
-
2.75 3.0
dB
40
60
-
dB
37
45
-
dB
33
40
-
dB
29
40
-
dB
20
25
-
P-P, Any 40MHz band for the
SAT1 /SAT2 /SAT3
Parameter
Group Delay Flatness
SAT 1 / SAT 2 / SAT 3
P-P, over each of the bands
dB
1
Units Max
nSec
25
dB
10
11
-
dB
10
11
-
dB
10
11
-
dB
10
11
-
dB
10
11
-
dB
10
11
-
SAT 1 / SAT 2 / SAT 3
P-P, over any 40MHz band
nSec
12
Pin Configuration
Function
SAT1 Port
SAT2 Port
SAT3 Port
Pin Number
1
4
7
* Restrictions on Hazardous Substances, European Union Directive 2002/95/EC
1 * Temperature Data available upon request
Common Port
Ground
14
2, 3, 5, 6,8-13, 15-20
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support