English
Language : 

LRH1025 Datasheet, PDF (5/15 Pages) LUXPIA – Specification for Approval




4. Electro-Optical Characteristics
(Ta=25°c)
item
rank symbol condition
min
typ
Max
unit
1
1.8
-
2.0
forward
2
2.0
-
2.2
voltage 2)
3
VF
IF= 20mA
2.2
-
2.4
4
2.4
-
2.6
Dominant
A-
Wavelength
λD
IF= 20mA
615
-
630
1E50
50
-
100
2E10
100
-
200
luminous
2E20
200
-
300
intensity 3)
2E30
IV
IF= 20mA
300
-
400
2E40
400
-
500
2E50
500
600
reverse
current
-
IR
VR=5V
-
-
50
2) Forward voltages are tested at a current pulse duration of 10 ms and an accuracy within ±0.1%.
3) The allowance of luminous intensity measurement is within ±10%.
* To avoid optical difference, please do not mix differently ranked product
V
nm
mcd
ɵ

4/16