LYG1006 Datasheet, PDF (4/14 Pages) LUXPIA – Specification for Approval | |||
|
◁ |
3. Absolute Maximum Ratings
item
symbol
forward current
IF
pulse forward current 1)
IFP
reverse voltage
VR
power dissipation
PD
operating temperature
Topr
storage temperature
Tstg
1) IFP conditions : pulse width ⤠10msec & duty ratio ⤠1/10
*Absolute Maximum ratings is not normal operating condition.
value
20
100
5
70
-30 to+85
-40 to +100
(Ta=25Â)
unit
mA
mA
V
mW
Â
Â
4. Electro-Optical Characteristics
(Ta=25Â)
item
rank symbol condition
min
typ
max
unit
V18
1.8
-
2.0
forward
voltage 2)
V20
VF
IF= 5mA
2.0
-
2.2
V
V22
2.2
-
2.4
YG0
568
-
570
Dominant
Wavelength3)
YG1
λD
IF= 5mA
570
-
572
nm
YG2
572
-
574
C
6
-
10
luminous intensity4) D
IV
IF= 5mA
10
-
14
mcd
E
14
-
20
reverse
current
-
IR
VR=5V
-
-
50
ɵ
2) Forward voltages are tested at a current pulse duration of 10 ms and an accuracy within ±0.1V.
3) The allowance of Dominant Wavelength measurement is within ±1nm%.
4) The allowance of luminous intensity measurement is within ±11%.
* To avoid optical difference, please do not mix differently ranked product
* All measurements were made under the standardized environment of LUXPIA.
5FOUBUJWF