English
Language : 

LYG1006 Datasheet, PDF (4/14 Pages) LUXPIA – Specification for Approval




3. Absolute Maximum Ratings
item
symbol
forward current
IF
pulse forward current 1)
IFP
reverse voltage
VR
power dissipation
PD
operating temperature
Topr
storage temperature
Tstg
  1) IFP conditions : pulse width ≤ 10msec & duty ratio ≤ 1/10
*Absolute Maximum ratings is not normal operating condition.
value
20
100
5
70
-30 to+85
-40 to +100
(Ta=25)
unit
mA
mA
V
mW


4. Electro-Optical Characteristics
(Ta=25)
item
rank symbol condition
min
typ
max
unit
V18
1.8
-
2.0
forward
voltage 2)
V20
VF
IF= 5mA
2.0
-
2.2
V
V22
2.2
-
2.4
YG0
568
-
570
Dominant
Wavelength3)
YG1
λD
IF= 5mA
570
-
572
nm
YG2
572
-
574
C
6
-
10
luminous intensity4) D
IV
IF= 5mA
10
-
14
mcd
E
14
-
20
reverse
current
-
IR
VR=5V
-
-
50
ɵ
2) Forward voltages are tested at a current pulse duration of 10 ms and an accuracy within ±0.1V.
3) The allowance of Dominant Wavelength measurement is within ±1nm%.
4) The allowance of luminous intensity measurement is within ±11%.
* To avoid optical difference, please do not mix differently ranked product
* All measurements were made under the standardized environment of LUXPIA.

5FOUBUJWF 