3. Absolute Maximum Ratings1)
item
symbol
forward current
IF
pulse forward current 2)
IFP
reverse voltage
VR
power dissipation
PD
operating temperature
Topr
storage temperature
Tstg
1) These values are based on 3-die performance
2) IFP conditions : pulse width ≤ 10msec & duty ratio ≤ 1/10
value
90
300
5
320
-30 to +85
-40 to +100
(Ta=25)
unit
mA
mA
V
mW


4. Electro-Optical Characteristics
(Ta=25)
item
rank symbol condition
min
typ
max
V29
2.9
-
3.0
V30
3.0
-
3.1
forward
voltage 3)
V31
VF
IF= 60mA
3.1
-
3.2
V32
3.2
-
3.3
V33
3.3
-
3.4
A0
450
-
455
Dominant
Wavelength
AL
λD
IF= 60mA
455
-
460
A
460
-
465
2E40
400
luminous
intensity 4)
2E60
IV
IF= 60mA
600
3E80
800
-
600
-
800
-
1000
3) Forward voltages are tested at a current pulse duration of 10 ms and an accuracy within ±0.1V.
4) The allowance of luminous intensity measurement is within ±11%.
* To avoid optical difference, please do not mix differently ranked product.
* All measurements were made under the standardized environment of LUXPIA.
unit
V
nm
mcd

7FS 