English
Language : 

OC100 Datasheet, PDF (2/4 Pages) List of Unclassifed Manufacturers – Opto Coupler
L U MINIS
Electrical controls
OPTIONS
Emergency battery back-up
EM42
One lamp:
EM242
Two lamp:
HOT
BLK
WHT
AC ballast
26w: 450 Lmns.. 26w / 32w
32w: 575 Lmns. 750 Lmns.
42w: 750 Lmns.
Time: 90 Mnts -120/277V / T 0º C
EM Ballast wiring
diagram for 120V
factory connection.
WHT
EM
ballast
If remote test switch
is required, please
add -S to option
Note:
*Unless otherwise specified, test switch and indicator
light are installed with luminaires at all times.
* Standard factory prewiring for
Unswitched luminaire.
Optional:
* EM42S
Switched luminaire wired for
external wall switch control.
* EM242S To be specified if required.
For 57w & 70w:
(Remote installation only) Consult factory
Note: Overall luminaire height will increase by 2” (50)
to accommodate battery back-up
COM
Quartz lamp restrike
Option: QRS
Quartz restrike standby lamp kit.
When power failure is restored, it
will energize temporary Quartz
lamp with progressive dimming
until full H.I.D light output is
produced.
max.100w DC bayonet type.
(Lamp is not included.)
Not Applicable with CFL lamps.
Black/120V (Factory wired)
Orange/277V
(Cap unused lead.)
Single pole test switch (Breaking the connection)
Electronic dimming ballast
Dimming specification
Specifying option
120V
277V
DM1-120
DM1-277
N0. of lamps
1X26/32/42W
DM2-120
DM2-277
2X26W
2DM2-120
2DM2-277
4X26W
DM3-120
DM3-277
2X32/42W
DM3-120
DM3-277
1X57/70W
DM4-120
DM4-277
2X57/70W
2DM3-120
2DM3-277
4X32/42W
3DM3-120
3DM3-277
6X32/42W
DM5-120
DM5-277
4X57/70W
Standard dimming ballast
MARK X 60HZ / EOL protection
Dimming;5-100% Min. start. temp. 10ºC (50ºF)
Burn lamps 100 hrs at full light output before dimming.
Quartz lamp emergency socket
Option: QS
Quartz lamp socket for external
120V emergency power input.
Separate 120V dedicated wiring is
included.
max.100 W DC bayonet type.
(Lamp is not included.)
Not Applicable with CFL lamps.
Pulse start ballast
Note: Add suffix PS to selected lamp wattage.
Use of pulse start lamp and ballast combination
requires a lens enclosure with the luminaire. Please
check with compatible luminaire lens option.
Note: Some pulse start lamps may be available as
protected lamp version to eliminate the lens
enclosure. If required, please contact factory to
verify availability and compatibility.
Dual switching
Luminaires ballasts
are wired for external
switching control.
DS1
++
-
DS2
+
+
++ +
+
-
DS1: Luminaires with
2 lamps individually
externally controlled.
DS2: Luminaires with
4 lamps or more are
externally controlled
by set of 2 lamps.(for
other lamp groupings,
please consult factory)
DS2: Luminaire ballast housing length
and stem size may be increased to
accomodate required number of ballasts.
DS1-26:
DS2-26:
DS1-42:
DS2-42:
DS1-70:
DS2-70:
DS1-120:
DS2-120:
DS2-642:
DS2-842:
DS2-657:
Dual single lamp switching 26W
Dual lamp switching by pair 2x26W
Dual single lamp switching 32W or 42W
Dual lamp switching by pair 2x32W or 2X42W
Dual single lamp switching 57W or 70W
Dual lamp switching by pair 2x57W or 2X70W
Dual single lamp switching 85W or 120W
Dual lamp switching by pair 2x85W or 2x120W
Dual lamp switching by pair 2x32W or 2X42W
Dual lamp switching by pair 2x32W or 2X42W
Dual lamp switching by pair 2x57W or 2X70W
Luminaires may be altered for design improvements or discontinued without prior notice.
LUMINIS [ USA ] - 3555 NW 53rd Court, Fort Lauderdale, FL.33309 Tel: 954 .717 .4155 Fax: 954 . 717.4157
LUMINIS [ Canada ] - 87 C Brunswick D.D.O. Q.C. Canada H9B 2J5 Toll free: 888 .401 .6999
Page 16
Web: www.luminis.com.
Sept. 2006 Rev.Feb.2007