English
Language : 

L1T2-3070000000000 Datasheet, PDF (6/19 Pages) Lumileds Lighting Company – Extreme efficacy that will transform your next market leading luminaire
Electrical Characteristics
Electrical Characteristics at 700 mA for LUXEON TX
Junction Temperature = 85°C
Table 3.
Nominal ANSI
CCT
Base
Part Number
Forward Voltage Vf [1] (V)
Minimum
Maximum
L1T2-2780000000000
2700K
L1T2-2785000000000
2.5
3.25
L1T2-2790000000000
L1T2-3070000000000
3000K
L1T2-3080000000000
L1T2-3085000000000
2.5
3.25
L1T2-3090000000000
3500K
L1T2-3580000000000
L1T2-3585000000000
2.5
3.25
L1T2-4070000000000
4000K
L1T2-4080000000000
2.5
3.25
L1T2-4085000000000
L1T2-5070000000000
5000K
L1T2-5080000000000
2.5
3.25
L1T2-5085000000000
5700K
L1T2-5770000000000
2.5
3.25
6500K
L1T2-6570000000000
2.5
3.25
Notes for Table 3:
1. Philips Lumileds maintains a tolerance of ±0.06V on forward voltage measurements.
2. Measured between Tj= 25°C and TJ= 110°C at If= 700 mA.
Absolute Maximum Ratings
Typical
Temperature Coefficient
of Forward Voltage [2] (mV/°C)
DVF / DTJ
-1.6
Typical
Thermal Resistance
Junction to Thermal Pad
(°C/W)
Ru J-C
3
-1.6
3
-1.6
3
-1.6
3
-1.6
3
-1.6
3
-1.6
3
Table 4.
Parameter
LUXEON TX
DC Forward Current [1] [2]
1050 mA
1200 mA
Peak Pulsed Forward Current [1] [3]
1200 mA
1350 mA
LED Junction Temperature [1]
150°C
135°C
ESD Sensitivity
< 8000V Human Body Model (HBM) Class 3A per JEDEC JS-001-2012
Operating Case Temperature at 700 mA
-40°C - 135°C
Storage Temperature
-40°C - 135°C
Soldering Temperature
JEDEC 020c 260°C
Allowable Reflow Cycles
3
Reverse Voltage (Vr) [4] [5]
LUXEON TX LEDs are not designed to be driven in reverse bias
Notes for Table 4:
1. Proper current derating must be observed to maintain junction temperature below the maximum.For additional information on thermal measurement guidelines please
refer to Application Brief AB106.
2. Residual periodic variations due to power conversion from alternating current (AC) to direct current (DC), also called “ripple”, with frequencies ≥100 Hz and amplitude
≤ 150 mA are acceptable, assuming the average current throughout each cycle does not exceed the maximum allowable DC Forward Current at the corresponding
maximum junction temperature.
3. Pulsed operation with a peak drive current equal to the stated Peak Pulsed Forward Current is acceptable if the pulse on-time is ≤ 5 ms per cycle and the duty cycle
is ≤ 50%.
4. Transient reverse voltages and surge currents due to electrical switching or supply interruptions are acceptable if these events do not last for more than 10ms, the
amplitude of the reverse voltage does not exceed 5V and the reverse current is less than 200μA.
5. Max 5V reverse for up to 10s is an acceptable beginning of life, one time test condition.
LUXEON TX Datasheet DS133 20131023 ©2013 Philips Lumileds Lighting Company.
5