English
Language : 

DS50 Datasheet, PDF (5/11 Pages) Lumileds Lighting Company – power light source LUXEON® Flash Module
Typical Forward Voltage (VF) vs. Drive Current (IF), TJ = 25ºC
1000
900
800
700
600
500
400
300
200
100
0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
Forward Voltage (V)
Figure 2. Typical Forward Voltage (VF) vs. Drive Current (IF), TJ = 25ºC
Absolute Maximum Ratings
Parameter
Table 2.
Max DC Operating Current (mA)
Peak Pulsed Forward Current (mA)
ESD Sensitivity[1] (volts HBM)
LED Junction Temperature (°C) [2]
Storage Temperature (°C)
Reflow Soldering Temperature (°C)
Ambient Operating Temperature (°C)
Moisture Sensitivity Level (JEDEC STD 020C)
Value
200
1000
2000
135
40 to +120
260 for 5 seconds max
40 to +85
1 Unlimited floor life (out of bag) at factory ambient
Notes for Table 2:
1. LUXEON Flash Modules are not designed to be driven in reverse bias. Philips Lumileds does not guarantee at reverse
bias conditions.
2. Tested in continuous drive mode.
LUXEON Flash Module Datasheet DS50 (6/06)
5