English
Language : 

LUXEON4014 Datasheet, PDF (4/14 Pages) Lumileds Lighting Company – Compact footprint delivering high-efficacy and just the right amount of light
Product Performance and Characterization Guide
Junction Temperature = 25ºC; Test Current at 30 mA and 60 mA
Table 1. Performance Characteristics at Tj = 25˚C, If = 30 mA
Nominal
CCT
Part Number
Luminous Flux @ 30 mA, 25°C
Minimum (lm)
Typical (lm)
Luminous Flux @ 60 mA, 25°C
Minimum (lm)
Typical (lm)
4000K
MXZ8-PW40-0000
10
12
18
22
Notes for Table 1:
1. Philips Lumileds maintains a tolerance of ±6.5% on luminous flux, ±2 on CRI, ±2 on R9 measurements.
2. Measured at Ts = 25°C, If = 30 mA.
CRI
Minimum
80
Typical
82
Absolute Maximum Ratings
Table 2. Operating Condition and Ratings PCB
Parameter
DC Forward Current
Peak Pulsed Forward Current
Maximum Performance
60 mA [2]
80 mA [3]
ESD Sensitivity
< 2000V Human Body Model (HBM) Class 2A JESD22-A114-E
< 400V Machine Model (MM) Class C JESD22-A115-B
Storage Temperature
-40°C - 100°C
LED Junction Temperature [1]
115°C
Operating Case Temperature at 60 mA
-40°C - 85°C
Reverse Voltage (Vr)
-5V
Notes for Table 2:
1. Proper current derating must be observed to maintain junction temperature below the maximum, please see preliminary application brief for additional information on
thermal measurement guidelines.
2. Residual periodic variations due to power conversion from alternating current (AC) to direct current (DC), also called “ripple’, with frequencies ≥ 100 Hz and amplitude
≤ 60 mA are acceptable, assuming the average current throughout each cycle does not exceed 60 mA.
3. Pulsed operation with a peak drive current of 80 mA is acceptable if the pulse on-time is ≤ 5 ms per cycle and the duty cycle is ≤ 50%.
LUXEON 4014 Datasheet DS205 20130502 ©2013 Philips Lumileds Lighting Company.
3