English
Language : 

GB-343 Datasheet, PDF (1/1 Pages) Lucky Light Electronic – Round-Helmet Type LED Lamps (5mm)
DESCRIPTION:
The 343 series are specially applied on short housing with wider angle
requirement.
It is in popular 5mm diameter package.
The semi-conductor materials used are:
GaP for (343HD/HT, 343GC/GD/GT)
GaAsP/GaP for (343RHC/RHD/RHT, 343YC/YD/YT and 343SD)
GB-343 SERIES
Round-Helmet Type
LED Lamps (5mm)
PACKAGE DIMENSIONS
5.8
Unit: mm
Tol: +/- 0.2mm
φ5.0
ABSOLUTE MAXIMUM RATINGS: (Ta=25oC)
Reverse Voltage
Reverse Current (Vr =5V)
Operating Temperature Range
Storage Temperature Range
Lead Soldering Temperature
(1.6mm (1/16)From Body)
5 Volt
100µA
-40oC To 85oC
-40oC To 100oC
260oC For 5 Seconds
NOTES : 1. All dimensions are in millimeters.
2. Lead spacing is measured where the leads emerge from the package.
3. Protuded resin under flange is 1.5 mm (0.059") Max.
4. Specifications are subject to change without notice.
1.0 Max.
6.0
1.6
25.4 Min.
0.5
1.0
2.54
PART NO. SELECTION AND APPLICATION INFORMATION (RATINGS AT 25oC AMBIENT)
Part No.
Emitted
Color
Lens
Color
Peak
Wavelength
λp (nm)
Vf (v)
Min Max
Rec.
If (mA).
Iv (mcd)
Min Typ.
View
Angle
2θ1/2(Deg)
GB-343HD
GB-343RHD
GB-343GD
GB-343YD
GB-343SD
GB-343HT
GB-343RHT
GB-343GT
GB-343YT
GB-343RHC
GB-343GC
GB-343YC
Bright Red
Bright Red
Green
Yellow
Orange
Bright Red
Bright Red
Green
Yellow
Bright Red
Green
Yellow
Red Diffused
Red Diffused
Green Diffused
Yellow Diffused
Orange Diffused
Red Trans.
Red Trans.
Green Trans.
Yellow Trans.
Water Clear
Water Clear
Water Clear
697
1.7 2.6 5-10 1.0 3.0
80
660
1.7 2.6 10-20 2.5 10.0
80
565
1.7 2.6 10-20 2.5 10.0
80
585
1.7 2.6 10-20 2.5 10.0
80
610
1.7 2.6 10-20 2.5 10.0
80
697
1.7 2.6 5-10 1.0 15.0
60
660
1.7 2.6 10-20 6.0 30.0
60
565
1.7 2.6 10-20 6.0 30.0
60
585
1.7 2.6 10-20 6.0 30.0
60
660
1.7 2.6 10-20 6.0 30.0
60
565
1.7 2.6 10-20 6.0 30.0
60
585
1.7 2.6 10-20 6.0 30.0
60
TESTING CONDITION FOR EACH PARAMETER :
PARAMETER:
REVERSE VOLTAGE
REVERSE CURRENT
FORWARD VOLTAGE
LUMINOUS INTENSITY
VIEWING ANGLE
RECOMMENDED OPERATING CURRENT
SYMBOL
Vr
Ir
Vf
Iv
2θ1/2
If (Rec)
UNIT
VOLT
µA
VOLT
MCD
DEGREE
mA
TEST CONDITION
Vr = 5.0 Volt
If = 20mA
If = 20mA
If = 20mA
0o
10o 20o
30o
1.0
C,T
D
40o
0.9
50o
0.8
60o
0.7
70o
80o
90o
0.5 0.3 0.1
0.2 0.4 0.6
SPATIAL DISTRIBUTION