LS7267 Datasheet, PDF (1/15 Pages) LSI Computer Systems – 24-BIT DUAL-AXIS QUADRATURE COUNTER
LSI/CSI
LS7267
U® L
LSI Computer Systems, Inc. 1235 Walt Whitman Road, Melville, NY 11747 (631) 271-0400 FAX (631) 271-0405
A3800
24-BIT DUAL-AXIS QUADRATURE COUNTER OCT 2015
FEATURES:
• Up to 50MHz count frequency in non-quadrature mode;
Up to 5.6MHz clock frequency (22 x 106 counts/sec) in
x4 quadrature mode.
• Dual 24-bit counters to support X and Y axes in
motion control applications. • Dual 24-bit comparators.
• Digital filtering of the input quadrature clocks
• Programmable 8-bit separate filter clock prescalers
for each axis.
• Error flags for noise exceeding filter band width.
• Programmable Index Input and other programmable I/Os.
• Independent mode programmability for each axis.
• Programmable count modes:
Quadrature (x1, x2, x4) / Non-quadrature,
Normal / Modulo-N / Range Limit / Non-Recycle,
Binary / BCD.
• 8-bit 3-State data I/O bus.
• 3V to 5.5V operation (VDD - VSS).
• TTL/CMOS compatible I/Os.
• LS7267 (DIP); LS7267-S (SOIC); LS7267-TS (TSSOP)
PIN ASSIGNMENT
TOP VIEW
YLCNTR/YLOL 1
FCK 2
V DD (+5V) 3
D0 4
D1 5
D2 6
D3 7
D4 8
D5 9
D6 10
D7 11
V SS (GND ) 12
C/D 13
WR 14
28 YRCNTR/YABG
27 YFLG1
26 YFLG2
25 YA
24 YB
23 XFLG2
22 XFLG1
21 XB
20 XA
19 XLCNTR/XLOL
18 XRCNTR/XABG
17 X/Y
16 RD
15 CS
LS7267 Registers:
LS7267 has a set of registers associated with each X and Y axis. All X-axis registers have the name prefix X,
whereas all Y-axis registers have the prefix Y. Selection of a specific register for Read/Write is made from the decode
of the three most significant bits (D7 - D5) of the data-bus. CS input enables the IC for Read/Write. C/D input selects
between control and data information for Read/Write. Following is a complete list of LS7267 registers.
Preset Registers: XPR and YPR
Each of these PRs are 24-bit wide. 24-bit data can be written into a PR, one byte at a time, in a sequence of three data
write cycles.
PR
7
07
07
0
HI BYTE
(PR2)
MID BYTE
(PR1)
LO BYTE
(PR0)
Counters: XCNTR and YCNTR
Each of these CNTRs are 24-bit synchronous Up/Down counters. The count clocks for each CNTR is derived from its
associated A/B inputs. Each CNTR can be loaded with the content of its associated PR.
Output Latches: XOL and YOL
Each OL is 24-bits wide. In effect, the OLs are the output ports for the CNTRs. Data from each CNTR can be loaded
into its associated OL and then read back on the data-bus, one byte at a time, in a sequence of three data Read
cycles.
OL
7
07
07
0
HI BYTE
(OL2)
MID BYTE
(OL1)
LO BYTE
(OL0)
Byte Pointers: XBP and YBP
The Read and Write operations on an OL or a PR always accesses one byte at a time. The byte that is accessed is
addressed by one of the BPs. At the end of every data Read or Write cycle on an OL or a PR, the associated BP is
automatically incremented to address the next byte.
7267-102215-1