English
Language : 

Q6008LH1LED Datasheet, PDF (5/6 Pages) Littelfuse – Q6008LH1LED series is designed to meet low load current characteristics typical in LED lighting applications.
Teccor® brand Thyristors
8 Amp Alternistor (High Commutation) Triac for LED dimmer application
Soldering Parameters
Reflow Condition
Pb – Free assembly
- Temperature Min (Ts(min))
Pre Heat - Temperature Max (Ts(max))
- Time (min to max) (ts)
Average ramp up rate (Liquidus Temp)
(TL) to peak
TS(max) to TL - Ramp-up Rate
Reflow
- Temperature (TL) (Liquidus)
- Temperature (tL)
Peak Temperature (TP)
Time within 5°C of actual peak
Temperature (tp)
Ramp-down Rate
Time 25°C to peak Temperature (TP)
Do not exceed
150°C
200°C
60 – 180 secs
5°C/second max
5°C/second max
217°C
60 – 150 seconds
260+0/-5 °C
20 – 40 seconds
5°C/second max
8 minutes Max.
280°C
Physical Specifications
Terminal Finish
100% Matte Tin-plated
Body Material
UL recognized epoxy meeting flammability
classification 94V-0
Terminal Material Copper Alloy
Design Considerations
Careful selection of the correct device for the application’s
operating parameters and environment will go a long way
toward extending the operating life of the Thyristor. Good
design practice should limit the maximum continuous
current through the main terminals to 75% of the device
rating. Other ways to ensure long life for a power discrete
semiconductor are proper heat sinking and selection of
voltage ratings for worst case conditions. Overheating,
overvoltage (including dv/dt), and surge currents are
the main killers of semiconductors. Correct mounting,
soldering, and forming of the leads also help protect
against component damage.
TP
TL
TS(max)
TS(min)
Ramp-up
Preheat
tS
25
time to peak temperature
tP
tL
Ramp-down
Time
Environmental Specifications
Test
AC Blocking (VDRM)
Temperature Cycling
Temperature/
Humidity
High Temp Storage
Low-Temp Storage
Thermal Shock
Autoclave
Resistance to
Solder Heat
Solderability
Lead Bend
Specifications and Conditions
MIL-STD-750, M-1040, Cond A Applied
Peak AC voltage @ 110°C for 1008 hours
MIL-STD-750, M-1051,
100 cycles; -40°C to +150°C; 15-min
dwell-time
EIA / JEDEC, JESD22-A101
1008 hours; 320V - DC: 85°C; 85%
rel humidity
MIL-STD-750, M-1031,
1008 hours; 150°C
1008 hours; -40°C
MIL-STD-750, M-1056
10 cycles; 0°C to 100°C; 5-min dwell-
time at each temperature; 10 sec (max)
transfer time between temperature
EIA / JEDEC, JESD22-A102
168 hours (121°C at 2 ATMs) and
100% R/H
MIL-STD-750 Method 2031
ANSI/J-STD-002, category 3, Test A
MIL-STD-750, M-2036 Cond E
Q6008LH1LED Series
5
Revised: January 25, 2013 08:34 AM
©2013 Littelfuse, Inc
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.