English
Language : 

Q6004L4 Datasheet, PDF (5/10 Pages) Littelfuse – 4 Amp bi-directional solid state switch series is designed for AC switching
Teccor® brand Thyristors
4 Amp Sensitive & Standard Triacs
Figure 9: On-State Current vs. On-State Voltage (Typical)
20
TJ = 25°C
18
16
14
12
10
8
6
4
2
0
0.6
0.8
1.0
1.2
1.4
1.6
1.8
Positive or Instantaneous
On-State Voltage (VT) - Volts
Figure 10: Surge Peak On-State Current vs. Number of Cycles
100
Qxx04Ry
Qxx04Ly
Qxx04Dy
Qxx04Vy
Lxx04Ry
10
Lxx04Ly
Lxx04Dy
Lxx04Vy
Supply Frequency: 60Hz Sinusoidal
Load: Resistive
RMS On-State [IT(RMS)]: Max Rated Value at
Specific Case Temperature
Notes:
1. G ate control may be lost during and immediately
following surge current interval.
2. O verload may not be repeated until junction
temperature has returned to steady-state
rated value.
1
1
10
100
1000
Surge Current Duration – Full Cycles
Note: xx = voltage, y = sensitivity
Lxx04xx & Qxx04xx Series
55
Revised: June 24, 2011 04:57 PM
©2011 Littelfuse, Inc
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.