English
Language : 

Q4010N5RP Datasheet, PDF (5/9 Pages) Littelfuse – 10 Amp Standard & Alternistor (High Communitation) Triacs
Teccor® brand Thyristors
10 Amp Standard & Alternistor (High Communitation) Triacs
Figure 7: Maximum Allowable Ambient Temperature
vs. On-State Current
120
110
CURRENT WAVEFORM: Sinusoidal
LOAD: Resistive or Inductive CONDUCTION
100
ANGLE: 360º
FREE AIR RATING - NO HEATSINK
90
80
Qxx10LHy
Qxx10RHy
70
60
Qxx10Ly
Qxx10Ry
50
40
30
20
0.0
0.2
0.4 0.6
0.8 1.0
1.2
1.4 1.6
1.8
2.0
RMS On-State Current [IT(RMS)] - AMPS
Figure 8: O n-State Current vs. On-State Voltage
(Typical)
20
18
16
14
12
10
8
6
4
2
0
0.7
TC = 25 ºC
0.8
0.9
1.0
1.1
1.2
1.3
1.4
Positive or Negative Instantaneous On-State Voltage
(VT) - Volts
Figure 9: S urge Peak On-State Current vs. Number of Cycles
1000
100
10
SUPPLY FREQUENCY: 60 Hz Sinusoidal
LOAD: Resistive
RMS On-State Current: [IT(RMS)]: Maximum Rated
Value at Specified Case Temperature
Notes:
1. G ate control may be lost during and immediately
following surge current interval.
2. O verload may not be repeated until junction
temperature has returned to steady-state
rated value.
1
1
10
100
1000
Surge Current Duration - Full Cycles
Qxx10xx & Qxx10xHx Series
93
Revised: November 1, 2010 05:04 PM
©2010 Littelfuse, Inc
Specifications are subject to change without notice.