English
Language : 

L0109MTRP Datasheet, PDF (3/8 Pages) Littelfuse – Teccor brand Thyristors Teccor brand Thyristors
Teccor® brand Thyristors
EV Series 1 Amp Sensitive Triacs
Figure 1: Definition of Quadrants
ALL POLARITIES ARE REFERENCED TO MT1
MT2 POSITIVE
MT2
(Positive Half Cycle)
+
MT2
(-) I GT
GATE
- I G T
MT1
REF
MT2
(+) I GT
GATE
MT1
QII QI
QIII QIV
REF
MT2
+ IGT
(-) I GT
GATE
(+) I GT
GATE
MT1
-
REF
MT2 NEGATIVE
(Negative Half Cycle)
MT1
REF
Figure 3: Normalized DC Holding Current
vs. Junction Temperature
3.0
INITIAL ON-STATE CURRENT = 100mA (DC)
2.5
2.0
1.5
1.0
0.5
0.0
-55 -40
-15
+5
+25 +45 +65 +85
Junction Temperature (TJ)- ºC
+105 +125
Figure 2: N ormalized DC Gate Trigger Current for
All Quadrants vs. Junction Temperature
3.0
2.0
1.0
0.0
-40
-15
+25
+65
Junction Temperature (TJ)- ºC
+105 +125
Figure 4: N ormalized DC Gate Trigger Voltage for
All Quadrants vs. Junction Temperature
2.00
1.75
1.50
1.25
1.00
0.75
0.50
0.25
0.0
-55 -40
-15
+5
+25 +45 +65 +85
Junction Temperature (TJ)- °C
+105 +125
Figure 5: Power Dissipation (Typical)
vs. RMS On-State Current
2.00
1.75
1.50
CURRENT WAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360°
1.25
1.00
0.75
0.50
0.25
0.0
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1
RMS On-state Current [IT(RMS)] - Amps
Figure 6: M aximum Allowable Case Temperature
vs. On-State Current
130
CURRENT WAVEFORM: Sinusoidal
125
LOAD: Resistive or Inductive
120
CONDUCTION ANGLE: 360°
SOT-223 CASE TEMPERATURE: Measured as
shown on dimensional drawings
110
100
90
TO-92
80
70
60
50
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2
RMS On-state Current [IT(RMS)] - Amps
L01 Series
45
Revised: June 21, 2011 04:14 PM
©2011 Littelfuse, Inc
Specifications are subject to change without notice.
Please refer to http://www.littelfuse.com for current information.